Installation Instructions

 

ELEKTROMAT 
SI 40.15-40,00 Ex

 

Model: 10002592 00013

 

 

 
 
 
 
 
 
 
 
 

 

-en- 

 

Status: 22.11.2019

 

 

 

Summary of Contents for 10002592 00013

Page 1: ...f Installation Instructions ELEKTROMAT SI 40 15 40 00 Ex Model 10002592 00013 en Status 22 11 2019...

Page 2: ...2 GfA ELEKTROMATEN GmbH Co KG Wiesenstra e 81 D 40549 D sseldorf www gfa elektromaten de info gfa elektromaten de...

Page 3: ...tion of the motor 17 11 Limit switch connection 17 12 Emergency manual operation emergency hand crank 18 13 Completion of commissioning testing operation 20 14 Declaration of conformity Motor 24 15 De...

Page 4: ...sks are to be performed by skilled personnel only Only trained electrical craftsmen are permitted to work on electrical equipment They must assess the tasks assigned to them recognise potential danger...

Page 5: ...PR03 Supply voltage 3 400 V Operating current 2 70 A Operating frequency 50 Hz Power factor cos 0 76 Maximum movements per hour 20 h 1 Manual force emergency manual operation 136 N Protection class IP...

Page 6: ...85F 92 T3 Manufacturer GfA Explosion protection II 2G Ex h IIC T3 Gb II 2D Ex h IIIC 190 C Db Max output torque 400 Nm Max output speed 19 rpm Shaft centre distance 85 mm Transmission ratio 1 92 Tempe...

Page 7: ...IP65 T 125 C Certificate of verification TUV IT 14ATEX021X Supply voltage 230 400 10 V Operating current 4 68 2 70 A Operating frequency 50 Hz Power 1 1 kW Power factor cos 0 76 Motor speed 1430 rpm M...

Page 8: ...6 20 40 T5 20 55 C Protection class IP 66 6 Technical data of limit switch emergency manual operation switch Type 07 2511 113061G Manufacturer Bartec Explosion protection II 2G Ex d IIC T6 II 2D Ex tD...

Page 9: ...walls mountings connection and transmission elements must not be exceeded even for maximum holding or locking torque observe technical data Connection elements Use self locking connection elements wi...

Page 10: ...10 Permissible mounting positions BAGAC03005_Z001 Mounting 2 elongated holes are provided for mounting BAGAD03001_Z003...

Page 11: ...her defined The door manufacturer s specifications must also be observed Warning Injury or danger to life possible Use a lifting device with sufficient load carrying capacity for installation tasks Co...

Page 12: ...ve unit BAGAE3007_Z001 Tighten all connection elements M12 with a torque of 75 Nm Install all further connection elements according to the specifications of the door manufacturer BAGAE03012_Z001 75 Nm...

Page 13: ...ect the cables mains OFF and check that the supply is off Observe the applicable regulations and standards Ensure proper electrical connection Use suitable tools Carrying out the electrical installati...

Page 14: ...uit protection is also required Excess current must be set on the basis of the IA IN ratio Completing the electrical installation Install cable entries and or cable glands In order to achieve the requ...

Page 15: ...by pressing the OPEN push button of the control If the door closes L1 and L2 must be swapped in a de energised state Setting of OPEN final limit position Open to the desired OPEN final limit position...

Page 16: ...1 EMERGENCY OPEN limit switch is preset by the setting of the OPEN final limit position The door must stop without posing any risks should the rotating direction be incorrect or should there be a faul...

Page 17: ...M1 Motor 11 Limit switch connection S10 Manual operation X12 Terminal rail S1 Safety open limit switch S2 Safety close limit switch S3 Open limit switch S4 Close limit switch S5 Additional limit swit...

Page 18: ...the emergency manual operation must be carried out against the closed brake Warning Danger of the door dropping If you need to apply more than the permissible force of 390N according to DIN EN 12604...

Page 19: ...19 Plug in the crank and turn until it engages Open or close by turning the crank After use the crank may be attached to the drive unit Attach as illustrated...

Page 20: ...ires no maintenance or inspection Warning Danger of the door dropping In the case of a gearbox damage the internal safety brake is triggered to prevent the door from dropping The gearbox stalls Releas...

Page 21: ...y out functional test only between final limit positions Limit switches Check the final limit positions by opening and closing the door completely The safety zone must not be reached Entire drive unit...

Page 22: ...ove directive and that no new hazards arise from their assembly The assembled modules are intended only for installation in a door system Drive unit SI 40 15 40 00 Ex Part no 10002592 00013 Consisting...

Page 23: ...he product according to Directive II 2G Ex h IIC T3 Gb II 2D Ex h IIIC 190 C Db Notified body pursuant to Directive T V Nord Anlagetechnik GmbH Am T V 1 30519 Hannover Deutschland Registration number...

Page 24: ...24 14 Declaration of conformity Motor...

Page 25: ...25 15 Declaration of conformity Accessories...

Page 26: ...26...

Page 27: ...d complies with the provisions of the above mentioned directives Authorised representative to compile the technical documents is the undersigned D sseldorf 10 08 2018 Stephan Kleine CEO Signature The...

Page 28: ...28...