Brake
Warning - Potential injury or danger to life!
Carry out a brake test. Overrun depends on the door and its equipment. The
specifications of the door manufacturer must be observed.
Brake lift may only be used in the final limit position CLOSE for doors that have no
counter-balancing.
Warning - Potential injury or danger to life!
Lifecycle brake - change complete brake unit at:
Operation with mains supply after 250.000 cycles
Operation with Inverter after 1.000.000 cycles
In an environment that can affect the coefficient of friction of the brake pad (atmosphere with
oil, solvents, detergents, etc.), class of protection IP65i must be adopted.
Drive unit
Note!
Engage a qualified engineer to check the drive unit annually
Apply shorter inspection intervals for doors that are operated frequently