Signet 2537 Flowmeter

40 

80 

120 

160 

200 

11 

14 

40 

80 

120 

 

160 

 

200 

 

-18 

27 

49 

71 

93 

°F 

°C 

psi 

bar 

240 
115 

PVDF 

Polypropylene 

Fluid Conditions

Pressure/Temperature Ratings:

Polypropylene Body:

•  12.5 bar (180 psi) max. @ 20 °C (68 °F)

•  1.7 bar (25 psi) max. @ 85 °C (185 °F)

PVDF Body:

•  14 bar (200 psi) max @ 20 °C (68 °F)

•  1.7 bar (25 psi) max @ 85 °C (185 °F)

Intended Use: 

This product is intended for use in industrial water treatment 

and wastewater treatment applications where the chemical content and the 

#

 uid 

temperatures are consistent with the speci

!

 cations listed herein.

This device is not approved for use or installation in fl ammable liquids.

Chemical Compatibility

Georg Fischer Signet products are manufactured in a variety of wetted materials to suit various liquids and chemicals.

All plastic materials including typical piping types (PVC, PVDF, PP and PE) are more or less permeable to contained media, such as 

water or volatile substances, including some acids. This effect is not related to porosity, but purely a matter of gas diffusion through the 

plastic.

If the plastic material is compatible with the medium according to the application guidelines, the permeation will not damage the plastic 

itself. However, if the plastic encloses other sensitive components, as is the case with GF Signet plastic paddlewheel sensors, these 

may be affected or damaged by the media diffusing through the plastic body and rotor.

PVDF paddlewheel sensors may experience failure when used in hot nitric acid applications. PVDF is known to allow for substantial 

permeation of nitric acid constituents without being damaged itself. No clear guideline can be given here, since the damaging effect to 

the sensor is highly dependent on temperature, pressure and concentration.

Utilizing sensors in applications with aggressive substances is possible. On special request GF Signet can provide sensors with a 

different internal resin encapsulation (potting) that will delay the damaging effect of acids to the sensors.

The retaining nuts of paddlewheel sensors are not designed for prolonged contact with aggressive substances. Strong acids, 

caustic substances and solvents or their vapor may lead to failure of the retaining nut, ejection of the sensor and loss of the

process fl uid with possibly serious consequences, such as damage to equipment and serious personal injury. Retaining nuts 

that may have been in contact with such substances, e.g. due to leakage or spilling, must be replaced.

For all Special Product inquiries or to place an order, please email 

signet-specialproduct@georgfi scher.com.

Flow Switch Output

Relay Modes: 

 

Low, High

Time Delay: 

 

0.0 to 6400.0 seconds

Hysteresis: 

 

Adjustable in Engineering Units

Relay Specifi cations

Dry Contact SPDT: 

5 A @ 30 VDC, 5 A @ 250 VAC

Solid-State Relay: 

100 mA @ 40 VDC, 70 mA @ 33 VAC

Digital (S

3

L) output

Type:   

 

Serial ASCII, TTL level 9600 bps

Maximum Cable Length:  See Digital (S

3

L) speci

!

 cations

Current output (Passive 4 to 20 mA)

Loop Accuracy:   

±32 

$

A (@ 25 °C @ 24 VDC)

Loop Resolution:   

$

A

Temp. Drift: 

 

±1 

$

A per °C max.

Power Supply Rejection:   ±1 uA per V

Maximum Cable Length:   305 m (1,000 ft)

Max Loop Resistance: 

600 

%

 @ 24 VDC, 1 K

%

 @ 32 VDC

Standards & Approvals

•  UL

•  CE

•  Manufactured under ISO 9001 for Quality, ISO 14001 

for Environmental Management and OHSAS 18001 for 

occupational health and safety.

  

China RoHS (Go to www.gfsignet.com for details)

WARNING

Declaration of Conformity according to FCC Part 15

This device complies with Part 15 of the FCC rules. 

Operation is subject to the following two conditions:

(1) This device may not cause harmful interference, and,

(2) This device must accept any interference received, including 

interference that may cause undesired operation.

Summary of Contents for Signet 2537

Page 1: ...Digital S3 L or 4 to 20 mA This unit can be con gured on site directly through the built in user interface The 4 to 20 mA model provides a blind current loop output The Digital S3 L model provides a...

Page 2: ...re and concentration Utilizing sensors in applications with aggressive substances is possible On special request GF Signet can provide sensors with a different internal resin encapsulation potting tha...

Page 3: ...when the system is in operation These con gurations are not recommended because it is dif cult to keep the pipe full Installation Pipe fittings Georg Fischer Signet offers a wide selection of install...

Page 4: ...irectly into the conduit port For conduit with ISO threads use the black thread adapter included with the connector kit To comply with NEC requirements do not use any metal conduit in the installation...

Page 5: ...e Dry Contact Relay requires an external power source of 24 VDC 10 The Solid State Relay requires an external power source of 5 to 24 VDC Solid State Relay requires a pull up resistor 10K ohm recommen...

Page 6: ...key S1 is held down for three seconds the ow rate is displayed for 10 minutes before reverting back to the model name In the Multi Model if the Multi menu item is set to divider then the divided puls...

Page 7: ...0 to 9 page 9 Mode Select the output mode Total or Divider or On OFF page 10 P Factor As PULSE DIVIDER divides input freq 1 0000 to 99999 page 10 P Factor As PULSE TOTAL multiplies K Factor 1 0000 to...

Page 8: ...tion Save the new setting Select the volumetric units for the ow measurement Flow Units Example Set the Flow Units to Gallons per minute This function is available on these versions of the 2537 2s 2s...

Page 9: ...ING only AVERAGING and SENSITIVITY Averaging and Sensitivity Settings Because ideal ow conditions are often impossible to achieve the ow rate is often erratic which causes erratic readings in control...

Page 10: ...Factor MULTIPLIED by the P factor The resulting frequency is output through a relay 2s Go to next menu item Return to Normal Operation Save the new setting Select DIVIDER or TOTAL operation The facto...

Page 11: ...hes the setpoint the 2537 will wait this long in seconds before triggering the alarm The factory setting is 0000 0 seconds 4 Program the DELAY A HI alarm will be activated when the ow rate rises ABOVE...

Page 12: ...T020 54 468 14 391 STAINLESS STEEL TEES ON SCH 40 PIPE 1 2 CR4T005 734 20 193 98 3 4 CR4T007 412 10 108 88 1 CR4T010 252 70 66 764 1 1 4 CR4T012 128 12 33 849 1 1 2 CR4T015 77 320 20 428 2 CR4T020 45...

Page 13: ...00 1 9868 8 CR4W080 4 3400 1 1466 CARBON STEEL WELDOLETS ON SCH 40 PIPE 2 1 2 CS4W025 37 600 9 9339 3 CS4W030 24 340 6 4306 4 CS4W040 13 920 3 6777 5 CS4W050 10 860 2 8692 6 CS4W060 7 5200 1 9868 8 CS...

Page 14: ...it breaks the sensor cannot be repaired 3 Install the new rotor by inserting one tip of the pin into the hole then carefully ex the opposite ear back enough to slip rotor into place H Dimensions The p...

Page 15: ...15 Signet 2537 Flowmeter Notes...

Page 16: ...Digital S3 L Integral Mount 3 2537 6C T0 159 001 320 4 to 20 mA Integral Mount Accessories Mfr Part No Code Description 3 2536 320 1 198 820 052 Rotor PVDF Black 3 2536 320 2 159 000 272 Rotor PVDF Na...

Reviews: