53
I
E
Open the operating lever (3) and the flared pipe
end is released.
Remark
If the clamping unit shall be released
without expanding the pipe, the lever must be
opened carefully, otherwise the high opening
speed could bring an uncontrolled fall out of the
clamping jaws.
Carry out the expansion process by closing
the operating lever (3).
Remark
Expansion of JRG Sanipex
pipes made of PE-X
After the flaring of flexible JRG
Sanipex pipes PE-X, the connection