background image

7

Signet 9900 Modbus Module

Unit of Measure

Code

Description

Flow (Primary)

GPS

22

Gallons per Second

GPM

16

Gallons per Minute

GPH

136

Gallons per Hour

GPD

235

Gallon per Day

LPS

24

Liters per Second

LPM

17

Liters per Minute

LPH

138

Liters per Hour

M3/M

131

Cubic Meters per Minute

M3/H

19

Cubic Meters per Hour

M3/D

29

Cubic Meters per Day

FT3/M

15

Cubic Feet per Minute

FT3/H

130

Cubic Feet per Hour

FT3/D

27

Cubic Feet per Day

MG/D

23

Million Gallons per Day

ML/D

25

Million Liters per Day

BPM

133

Barrels per Minute

BPH

134 242

Barrels per Hour

BPD

135

Barrels per Day

FT/S

20

Feet per Second

M/S

21

Meters per Second

All Others

252

All other fl ow units

Flow Totalization (Secondary)

All Units

240

pH (Primary)

pH

59

pH

pH Temperature (Secondary) Important Requires power cycle to update

Temperature C

32

Degrees Celsius

Temperature F

33

Degrees Fahrenheit 

ORP (Primary and Secondary)

mV

36

Millivolts

Conductivity (Primary)

uS

67

microSiemens

mS

66

milliSiemens

PPM

139

Parts per Million

PPB

169

Parts per Billion

KOhms

163

Kilo Ohms

MOhms

170

Mega Ohms

Conductivity Temperature (Secondary)

Temperature C

32

Degrees Celsius

Temperature F

33

Degrees Fahrenheit 

Pressure 

PSI

6

Pounds per Square Inch

Bar

7

Bars

KPa

12

Kilopascals

Programming Map

Summary of Contents for 3-9900.270-MX

Page 1: ...efore or after the base unit is mounted If the 9900 Base Unit will be mounted using the accessory wall mount kit 3 9900 392 install plug in modules rst If the Direct Conductivity Resistivity Module or...

Page 2: ...y Information Product Registration Safety Information CAUTION Exercise care when installing module Do not bend connecting pins Align pins and connectors then push module firmly into place Avoid Electr...

Page 3: ...White Gray D0 RS485 Pin 2 D1 RS485 Pin 1 V 12 to 24 VDC Pin 3 V 12 to 24 VDC Common Pin 4 Com Reset GND Pin 5 Brown D0 RS485 Yellow D1 RS485 Black V 12 to 24 VDC White V 12 to 24 VDC Common Gray Com...

Page 4: ...te Data Type Description 49104 1 Read UINT 9900 HSB Transactions 49105 1 Read UINT Second Counter 49106 1 Read UINT Bus Message Counter 49107 1 Read UINT Bus Message Error Counter 49108 1 Read UINT Sl...

Page 5: ...gister 49005 0 No Parity 1 Odd Parity 2 Even Parity Default 2 Set baud Rate Register 49004 0 1200 1 2400 2 4800 3 9600 4 19200 5 38400 6 57600 7 115200 Default 4 Write Modbus Address to Register 49007...

Page 6: ...5102 pH Temperature ORP 0x5103 ORP Raw mV Cond Res 0x5704 Cond Res Temperature Pressure 0x4105 Pressure NA Level Volume 0x5C06 Level Volume Temperature 0x4007 Temperature NA 4 to 20 mA Input 0x0008 Sc...

Page 7: ...e BPH 134 242 Barrels per Hour BPD 135 Barrels per Day FT S 20 Feet per Second M S 21 Meters per Second All Others 252 All other ow units Flow Totalization Secondary All Units 240 pH Primary pH 59 pH...

Page 8: ...ssembly for M2 3 9900 270 CB3 159 200 125 Replacement M12 Connector Assembly for M3 3 9900 270 CB4 159 200 129 Replacement Cable Assembly for M4 5541 5005 159 855 021 5 meter 16 ft M12 cable 5541 5010...

Reviews: