Hook bolt lock, Lock M
3
Safety notices
Symbols and illustrations
Symbols and illustrations
In order to illustrate proper operation, important information and technical information is highlighted.
Symbol
Meaning
means "important information";
Information on avoiding material damage, understanding a concept or optimising the operation sequences
means “additional Information”
X
Symbol for an action: there is something you must do here.
X
If there are several actions to be taken, keep to the given order.
Product liability
In compliance with the liability of the manufacturer for his products as defined in the German "Product Liability
Act", compliance with the information contained in this brochure (product information and intended use, misuse,
product performance, product maintenance, obligations to provide information and instructions) must be en-
sured. Failure to comply releases the manufacturer from their statutory liability.
1
Safety notices
To ensure personal safety, it is important to follow these safety instructions.
These instructions must be kept.
1.1 Intended use
The hook bolt lock Lock M is only suitable for use
à
in dry rooms,
à
in automatic door systems for horizontal door leaves,
à
in entrances and interior areas of pedestrian traffic in commercial plants and public areas.
The hook bolt lock Lock M must not be used on fire and smoke protection doors.
1.2 Safety notices
à
The mandatory installation, maintenance and repair work must be performed by properly trained personnel
authorised by GEZE.
à
The country-specific laws and regulations are to be observed during safety-related tests.
à
If unauthorised changes are made to the system, GEZE cannot be held liable in any way whatsoever for any
resulting damage, and the approval for use in escape and rescue routes ceases.
à
GEZE makes no guarantee for combinations with third-party products.
à
Furthermore, only original GEZE parts may be used for repair and maintenance work.
à
The connection to the mains voltage must be made by a professional electrician. Perform the power connec-
tion and equipment earth conductor test in accordance with VDE 0100 Part 610.
à
Use an on-site 10-A overload cut-out as the line-side disconnecting device.
à
In compliance with Machinery Directive (2006/42/EC), a risk analysis must be performed and the door system
identified in accordance with CE Marking Directive 93/68/EEC before the door system is commissioned.
à
Observe the current status of directives, standards and country-specific regulations, especially:
à
DIN 18650 “Automatic door systems – product requirements and test methods” and
EN 16005 “Power-operated pedestrian doorsets – safety in use – requirements and test methods”
à
VDE 0100, Part 610 "Installing Electrical Power Systems with Nominal Voltages up to 1000 V"
à
Accident-prevention regulations, especially BGV A1 "General regulations" and BGV A2 "Electrical systems
and equipment"
à
DIN EN 60335-2-103 "Household and similar electrical appliances; Particular requirements for drives for
gates, doors and windows"