background image

 

page 4   |   

7”

 TOUCH PANEL

   |   PROGRAMMING MANUAL

 

TECHNICAL DATASHEET 

Technical data

 

P

ROCESSOR

 

MT8127A/B 1.3GHz Quad Core Cortex-A7 

RAM 

2GB DDR3L SDRAM 

F

LASH MEMORY

 

8GBeMMC 

P

OWER SUPPLY

 

12V-24V DC  
PoE (802.3af) 

P

OWER SUPPLY ABSORPTION

 

< 13W 

C

OMMAND ELEMENTS

 

1 on/off button 

I

NPUTS

 

1 4-pole extractable screw terminal for: 

-

 auxiliary power supply (marked with + and - Vdc) 

-

 auxiliary input (marked with 1 and 2) 

Maximum cable section: 2.5 mm

LCD 

D

IMENSIONS

7" TFT 

R

ESOLUTION

1024 x 600 

V

IEWING ANGLE

80° from the left, 80° from the right, 60° from above, 70° from 
below 

L

IFESPAN

20000 h 

C

ONTRAST

800:1 

L

IGHT INTENSITY

340 [cd/m

2

T

OUCH

 

Capacitive (5-point multi-touch) 

V

IDEO CAMERA

 

2M Pixel FF 
Video compression H.264 

A

UDIO

 

1 omnidirectional microphone 
2 speakers 
Support for echo cancellation for two-way conversations 
Audio compression G.711 

I

NTERFACES

 

1 RJ45 Ethernet network 10/100 Mbit/s (PoE) 
1 slot for micro SD 
1 micro USB port 

R

ADIO CONNECTION

 

Wi-Fi IEEE 802.11 a/b/g/n (2.4GHz/5GHz) 

O

PERATING TEMPERATURE

 

-5 to +45°C 

S

TORAGE TEMPERATURE

 

-25 to +55°C 

D

EGREE OF PROTECTION

 

IP20 

D

IMENSIONS 

(L

 X 

H

 X 

D) 

196 x 128 x 19.3 mm 

R

EGULATORY REFERENCES

 

RoHS 2011/65/EU + 2015/863/EU 

Gewiss declares that the radio article GW9007CB complies with Directive 2014/53/EU. The complete 
text of the EU declaration is available at the following Internet address

www.gewiss.com

 

 

 

 

Summary of Contents for CHORUS GWA9007CB

Page 1: ...TOUCH PANEL 7 GWA9007CB Programming manual ...

Page 2: ... ENCLOSURE 14 ADDING AN OUTDOOR INDOOR POSITION TO THE LIST OF INTERCOMS 16 ADDING A PUSH BUTTON TO THE OUTDOOR POSITION FOR OPENING A DOOR OR SWITCHING ON A STAIR RAISER LIGHT 18 MODIFYING AN OUTDOOR POSITION THAT HAS ALREADY BEEN CONFIGURED 22 DELETING A PUSH BUTTON FROM AN OUTDOOR POSITION THAT HAS ALREADY BEEN CONFIGURED 23 CHECKING THE COMMUNICATION BETWEEN THE PANEL AND THE OUTDOOR POSITION ...

Page 3: ...GRAMMING MANUAL page 3 AIM OF THIS PUBLICATION This manual provides the information needed to configure the panel and associate the various indoor outdoor video intercom positions It is therefore aimed at the installer ...

Page 4: ...RAST 800 1 LIGHT INTENSITY 340 cd m2 TOUCH Capacitive 5 point multi touch VIDEO CAMERA 2M Pixel FF Video compression H 264 AUDIO 1 omnidirectional microphone 2 speakers Support for echo cancellation for two way conversations Audio compression G 711 INTERFACES 1 RJ45 Ethernet network 10 100 Mbit s PoE 1 slot for micro SD 1 micro USB port RADIO CONNECTION Wi Fi IEEE 802 11 a b g n 2 4GHz 5GHz OPERAT...

Page 5: ...ush button 2 Slot for micro SD card 3 Micro USB socket outlet 4 Loudspeakers 5 Camera 6 Microphone 7 RJ45 Ethernet socket outlet 8 Auxiliary power supply terminals 12 24 Vdc marked with and Vdc 9 Terminals for potential free auxiliary input marked with 1 and 2 1 2 3 4 4 5 6 7 8 9 ...

Page 6: ...X Standard communication protocol for HA BA applications LAN Local Area Network VEIM or IM Video Entryphone Indoor Monitor PoE Acronym of Power over Ethernet a technique for powering devices using the same cable that connects them to the Ethernet data network VEOS or OS Video Entryphone Outdoor Station Zigbee Wireless standard communication protocol FUNCTIONS OF THE 7 PANEL Video intercom Answer c...

Page 7: ...tercom network a single network for all the devices same IP network class Using a VoIP SIP enclosure to be connected to the same LAN as the video intercom system The use of the enclosure allows the above limits to be exceeded and also offers the following advantages PI any SIP device on the market can be used The video intercom call can also be forwarded to any device of the public telephone netwo...

Page 8: ...rtment LAN via a Wi Fi connection if you want to control the Smart Home system too Smart Gateway can be connected to the apartment LAN via a Wi Fi or Ethernet connection If additional indoor video intercom positions are needed in an apartment two touch panels can be installed Apartment N Apartment 2 Apartment 1 Detail of apartments Outdoor positions example 2N 7 touch panel 7 touch panel 7 touch p...

Page 9: ...nection if you want to control the Smart Home system too Smart Gateway can be connected to the apartment LAN via a Wi Fi or Ethernet connection If additional indoor video intercom positions are needed in an apartment several touch panels can be installed Apartment N Detail of apartments Outdoor positions example 2N 7 touch panel 7 touch panel 7 touch panel 7 touch panel Apartment Wi Fi Apartment L...

Page 10: ...nerated by VoIP calls Use network switches with the following characteristics Transmission speed 10 100 1000 Mbit Professional not consumer type switches of renowned brands that can guarantee product quality and reliability Meeting the requirements of the type of installation board or surface mounting and the space occupied Presence of PoE ports if necessary to power the panels in condominiums it ...

Page 11: ...SIP VoIP server See Architecture 1 condominiums and multi family houses with video intercom without a local VoIP SIP enclosure and possibly domotics a SIP port optional only if different from the standard 5060 SIP port due to installation requirements the DTMF code for activating the outdoor position relay if it is directly used to open the gate door or the URL http for activating the web relays u...

Page 12: ...es for opening doors gates 3 Configure the touch panels on the basis of the SIP number assigned to the indoor position and the possible IP address assigned Assigning a static IP address to the touch panel With reference to architecture 1 to assign a static IP address to the panel Ethernet board you must 1 Click on the Settings icon on the home page 2 Select Ethernet on the Settings page 3 In the E...

Page 13: ...7 TOUCH PANEL PROGRAMMING MANUAL page 13 4 Close the Settings page by pressing on the lower bar ...

Page 14: ...used person calling to establish the call to the panel itself SIP port the port used for the SIP calls only specify it if you want to use a door other than the standard 5060 one Authentication the credential used by the panel to authenticate itself for an intended user that requires authentication e g a local VoIP SIP enclosure leave this field empty if the communication doesn t require authentica...

Page 15: ...7 TOUCH PANEL PROGRAMMING MANUAL page 15 5 After filling in the fields press Save ...

Page 16: ...ion SIP number the SIP number reserved for the outdoor indoor position used by the panel to establish the call to the position and to identify the person calling in the case of an incoming call IP address the IP address assigned to the outdoor indoor position used to contact the position to be filled in only for systems using architecture 1 SIP port the port used by the outdoor indoor position to ...

Page 17: ...g the gate or switching on the stair raiser light ref Adding a push button to the outdoor position for opening a door or switching on a stair raiser light 5 After filling in all the fields press Save 6 The panel will return to the video intercom home page where the newly associated outdoor position will be shown ...

Page 18: ...n Add button at the bottom of the page if you want to add a push button up to 5 for Open door gate commands and or http command for using the web relays Follow the procedure 1 Click on Add button 2 Fill in the fields on the page that opens Button label the text below the push button shown during the call e g Open Icon the type of icon you want to use for the push button being added Button type DTF...

Page 19: ...7 TOUCH PANEL PROGRAMMING MANUAL page 19 ...

Page 20: ... the necessary fields press Save 4 The panel will return to the video intercom home page If the configuration has been made correctly the newly added push button will appear when the communication with the outdoor position is opened clicking on the telephone receiver icon ...

Page 21: ...7 TOUCH PANEL PROGRAMMING MANUAL page 21 ...

Page 22: ...oceed as follows 1 Open the Video intercom app 2 On the video intercom home page keep your finger pressed on the position you want to modify A drop down menu will appear with two items a Edit b Delete 3 Click on Edit 4 A page containing the position configuration parameters will open 5 Press directly on a parameter to activate the modification If you want to configure a new push button refer to Ad...

Page 23: ...o intercom home page keep your finger pressed on the outdoor station you want to modify A drop down menu will appear with two items a Edit b Delete 3 Click on Edit 4 A page containing the outdoor position configuration parameters will open 5 Scroll down the page to find the additional push button you want to delete Click on the arrow to its right 6 On the page showing the configuration parameters ...

Page 24: ...page 24 7 TOUCH PANEL PROGRAMMING MANUAL ...

Page 25: ...unication between the panel and the outdoor position Once the configuration procedure has been completed the outdoor position will appear on the video intercom home page Click on the telephone receiver icon to open the communication with that outdoor position ...

Page 26: ...ick on this icon to deactivate the panel microphone Push button click on this icon to open the door gate or switch on the light depending on how the push button associated with the outdoor position has been configured Close to end the communication with the outdoor position ...

Page 27: ...outdoor indoor position Proceed as follows Open the Video intercom app On the video intercom home page keep your finger pressed on the outdoor indoor position you want to delete A drop down menu will appear with two items i Edit ii Delete Click on Delete ...

Page 28: ... for staircase B 3 indoor positions for the apartments of staircase A two for apartment 1 and one for apartment 2 2 indoor positions for the apartments of staircase B one for each apartment To configure the outdoor positions refer to the relative installation manual provided by the manufacturer Apartment 2A Apartment 4B Apartment 3B Staircase B entrance Main entrance Staircase A entrance Apartment...

Page 29: ... push button ref Adding a push button to the outdoor position for opening a door or switching on a stair raiser light a Push button text Open b Icon Key c Push button type DTMF d DTMF code 1 Outdoor position Staircase A entrance ref Adding an outdoor indoor position to the list of intercoms i Name Staircase A entrance ii SIP number 100 iii IP address 172 16 2 100 iv SIP port 5060 v Add a DTMF push...

Page 30: ...ush button ref Adding a push button to the outdoor position for opening a door or switching on a stair raiser light a Push button text Open b Icon Key c Push button type DTMF d DTMF code 1 Indoor position intercom Apartment 1A living area ref Adding an outdoor indoor position to the list of intercoms i Name Living area panel ii SIP number 111 iii IP address 172 16 2 111 iv SIP port 5060 Panel Apar...

Page 31: ... access the Internet DNS Can remain empty if the network does not need to access the Internet Configuration of the panel SIP number and port ref Configuring the SIP number and port assigned to the panel and any parameters associated with the local VoIP enclosure i IP address of the server empty ii SIP port of the server empty iii SIP number 210 iv SIP port 5060 v Authentication empty vi Password e...

Page 32: ...ii SIP number 220 iv SIP port 5060 v Authentication empty vi Password empty Outdoor position Main entrance ref Adding an outdoor indoor position to the list of intercoms i Name Main entrance ii SIP number 10 iii IP address 172 16 2 10 iv SIP port 5060 v Add a DTMF push button ref Adding a push button to the outdoor position for opening a door or switching on a stair raiser light a Push button text...

Page 33: ...P SIP enclosure it s assumed that it has been configured to assign addresses in the range 172 16 2 xxx and that 172 16 2 5 is RESERVED for the SIP server i e outside the assignment range of the server or in static DHCP reservation on the MAC address of the SIP server Apartment 2A Apartment 4B Apartment 3B Staircase B entrance Main entrance Staircase A entrance Apartment 1A Living area Apartment 1A...

Page 34: ...text Open b Icon Key c Push button type DTMF d DTMF code 1 Outdoor position Staircase A entrance ref Adding an outdoor indoor position to the list of intercoms i Name Staircase A entrance ii SIP number 100 iii IP address empty iv SIP port empty v Add a DTMF push button ref Adding a push button to the outdoor position for opening a door or switching on a stair raiser light a Push button text Open b...

Page 35: ...a ref Adding an outdoor indoor position to the list of intercoms i Name Living area panel ii SIP number 111 iii IP address empty iv SIP port empty Panel Apartment 2A IP configuration ref Assigning a static IP address to the touch panel i DHCP enabled Configuration of the panel SIP number and port ref Configuring the SIP number and port assigned to the panel and any parameters associated with the l...

Page 36: ...0 iii IP address empty iv SIP port empty v Add a DTMF push button ref Adding a push button to the outdoor position for opening a door or switching on a stair raiser light a Push button text Open b Icon Key c Push button type DTMF d DTMF code 1 Outdoor position Staircase B entrance ref Adding an outdoor indoor position to the list of intercoms i Name Staircase B entrance ii SIP number 200 iii IP ad...

Page 37: ...oor or switching on a stair raiser light a Push button text Open b Icon Key c Push button type DTMF d DTMF code 1 Outdoor position Staircase B entrance ref Adding an outdoor indoor position to the list of intercoms i Name Staircase B entrance ii SIP number 200 iii IP address empty iv SIP port empty v Add a DTMF push button ref Adding a push button to the outdoor position for opening a door or swit...

Page 38: ... page will appear You will need the access credentials for the specific domotics account that you want to associate with the 7 touch panel 3 Click on Sign in 4 Permission will be requested to access the information of the profile being associated Approve Consent is given for this specific access moment only With every new access consent will be requested again Approve always Permanent consent is g...

Page 39: ... the necessary consent for data processing read the contents carefully scrolling down the page Make sure you have filled in all the fields 6 Once the procedure has been completed the domotics home page will open showing the system that has been associated with the panel It works in the same way as the Smart Gateway app refer to the relative user manual ...

Page 40: ...GUAGE SELECTION Settings menu how to find it If you want to access the complete device settings menu click on the gear icon on the panel home page On the page that opens you can see all the settings menus in the device Scroll down the page to see the complete list of menus 1 2 3 ...

Page 41: ...G THE LIGHT INTENSITY Click on Brightness level to see a window with a cursor that you can use to regulate the light intensity of the screen SETTING AUTOMATIC SCREEN SWITCH OFF STANDBY Click on Sleep to activate deactivate automatic screen switch off and regulate the time of inactivity after which the command is implemented 1 2 ...

Page 42: ...page 42 7 TOUCH PANEL PROGRAMMING MANUAL REGULATING THE CHARACTER SIZE Click on Font size to regulate the dimensions of the characters 1 2 ...

Page 43: ...CH PANEL PROGRAMMING MANUAL page 43 Changing the language When the settings page has opened select the item Language input On the page that opens click on Language Select the required language from the list ...

Page 44: ...me of notifications When the settings page has opened click on Sound and notifications On the page that opens click on the icon to the right of the item General On the page that opens drag the indicator next to the item Notification volume to regulate that item ...

Page 45: ... pressing sound When the settings page has opened click on Sound notification On the page that opens click on the icon to the right of the item General On the page that opens drag the indicator next to the item Touch sounds to the right or left to activate or deactivate the sound ...

Page 46: ...page 46 7 TOUCH PANEL PROGRAMMING MANUAL LAST REVISION 06 2020 code 7 01 9 399 0 ...

Reviews: