G-Cam/EWPC-2271
Installation
17
②
Sensor (DI) connection
Sensor (DI) can be connected to either a voltage type sensor or a relay type sensor.
Settings can be done through the camera’s webpage.
Input voltage range: 0VDC minimum to 5 VDC maximum, max. 50mA.
Do not exceed the maximum input voltage or relay rate.
③
Alarm (DO) connection
Only the relay type is supported.
Relay Rating: Max 24 VDC 50mA
Do not exceed the maximum relay rating.
+3.3V
DI
COM
DI
COM
+
-
Relay Type
Voltage Type
+
-
Output
of
Sensor
Output
of
Sensor
Internal
Internal
+
-