TROUBLESHOOTING
PROBLEM
SOLUTION
1) Vise isn’t holding cylinder
1) a. Adjust pressure to 100-140 PSI
b. Check for air leaks & repairs
2) Air leak in control valve
2) Replace valve
– P/N: 3G59484
3) Air leak in air cylinder body
3) Repair air cylinder cylinder P/N: 1G0397
4) Air blows out exhaust post
4) Repair air cylinder cylinder P/N: 1G0397
on air valve continuosly
5) Belt broken, worn, or torn
5) Replace belt
– P/N: 3G58512
Replace belt assembly
– P/N:3G58514
6) Bent air cylinder shaft
6) Replace air cylinder
– P/N: 53235 &
install belt roller kit
– P/N: 3G59407
Use the following kit for general service and maintenance
– P/N: 3G58895