1   INTRODUCTION

1.1   Intended use

The drying cabinet is designed for fast and sparing drying of
anesthetic tubing, such as hoses with smooth or corrugated
surfaces, bellows, breating masks and surgical instruments in
trays. All goods to be loaded must have passed an acknowledged
cleaning and disinfection process in a washer-disinfector.

The drying cabinet is designed for use in soiled and clean areas of
CSSDs, TSSUs and other departments where efficient drying of
equipment is important.

1.2   Product liability

1.2.1   Declaration of Conformity

The product compliance is stated in the Declaration of Conformity.

1.2.2   Disclaimer

The manufacturer cannot guarantee that the product will work
as intended if accessories or spare parts other than those
approved by the manufacturer are used.

The product liability only applies when the instructions in this
manual have been followed in their entirety.

The manufacturer accepts no responsibility for personal
injuries when the instructions in this manual have not been
followed in their entirety.

The manufacturer reserves the right to change the
specification and design of the product without any prior
notice. 

 

1.2.3   Manufacturer

This product was manufactured by:

GETINGE DISINFECTION AB
Ljungadalsgatan 11
PO Box 1505
SE-351 15 Växjö, Sweden

1.2.4   Warranty

The product warranty applies in accordance with the agreement
reached between the Getinge sales company and the customer.

1 INTRODUCTION

USER MANUAL GETINGE DRYING CABINET S-363

5 (24)

<Doc_6001300802><Rev.C><Lang_en>

Summary of Contents for S-363

Page 1: ...GETINGE DRYING CABINET S 363 USER MANUAL 6001300802 ...

Page 2: ...roduct This manual must not be modified reproduced or copied without GETINGE s written consent The content may not be reused by third parties or used for unauthorized purposes Violators will be prosecuted Additional copies of this manual can be obtained from GETINGE for a fee Copyright 2013 GETINGE Reprinting prohibited GETINGE DISINFECTION AB Ljungadalsgatan 11 PO Box 1505 SE 351 15 Växjö Sweden ...

Page 3: ...N 10 4 1 Free standing model 10 4 2 Manual discharge damper 11 5 ELECTRICAL INSTALLATION 12 5 1 Electrical connections 12 5 1 1 Connect electricity 12 5 1 2 Isolator switch 12 5 1 3 Connection diagram 13 5 1 4 Pre fuse requirements 13 6 DIRECTIONS FOR USE 14 7 ERROR CODE 1 15 7 1 Drying anaesthetic and respiratory hoses and bellows 15 7 2 Maintenance when necessary 15 7 3 Cleaning the filter casse...

Page 4: ...4 24 USER MANUAL GETINGE DRYING CABINET S 363 Doc_6001300802 Rev C Lang_en ...

Page 5: ...ntee that the product will work as intended if accessories or spare parts other than those approved by the manufacturer are used The product liability only applies when the instructions in this manual have been followed in their entirety The manufacturer accepts no responsibility for personal injuries when the instructions in this manual have not been followed in their entirety The manufacturer re...

Page 6: ... involved should study up to date handbooks and service manuals before undertaking any repairs or service work All leads must be disconnected from all circuit boards of the control system before commencing welding on or near the drying cabinet The drying cabinet should not be sprayed with water Use safety gloves when performing service due to risk for sharp edges At least two persons should work t...

Page 7: ...ext It gives warning of dangers which could lead to minor or major injury to the person and even to a fatality It is also used in warnings to avoid damage to the machine This symbol indicates a warning in the text concerning high voltage 2000 V It gives warning of dangers which could lead to minor or major injury to the person and even to a fatality 2 SAFETY INSTRUCTIONS USER MANUAL GETINGE DRYING...

Page 8: ...roximately 500 W if the exhaust stub pipe is connected to the exhaust ventilation Electrical Max current A Power kW Max Pre Fuse 200 V 3 PE 50 60 Hz 11 6 A 2 6 kW C16 A 230 V 3 PE 50 60 Hz 13 3 A 3 4 kW C16 A 240 V 3 PE 50 60 Hz 13 8 A 3 7 kW C16 A 400 V 3N PE 50 60 Hz 7 3 A 3 4 kW C10 A 415 V 3N PE 50 60 Hz 7 8 A 3 7 kW C10 A Pollution degree 2 Max altitude 2000 m Indoor use only Overvoltage cate...

Page 9: ... the drying time is complete the fan runs for an additional 2 minutes with the heater switched off so that the overheating cut out does not trip There are two heater settings 70 C for plastics and 90 C for rubber hoses and instruments The display alternates between and the drying time when the filter needs cleaning 3 1 1 Construction The cabinet is available as a single configuration or a through ...

Page 10: ...ke the whole handle in your hand If you open and closed the handle by taking the lower part of the handle it would not be possible to pinch a finger 004832 4 1 Free standing model Secure the machine firmly to the wall with two screws through the holes A at the top of the machine 004833 A 4 INSTALLATION 10 24 USER MANUAL GETINGE DRYING CABINET S 363 Doc_6001300802 Rev C Lang_en ...

Page 11: ...arger damper so it suits the ventilation capacity 004834 A B 1 2 1 2 A Wall hung singel door model S 363E 1 Handle 2 Discharge damper B Recessed two door pass through version hole in wall must be 615x2190 1 Handle 2 Discharge damper For ventilation requirements see section 3 TECHNICAL DATA 4 INSTALLATION USER MANUAL GETINGE DRYING CABINET S 363 11 24 Doc_6001300802 Rev C Lang_en ...

Page 12: ... type plate Install the machine in accordance with installation category CAT II Make sure the electrical connection is carried out in accordance with current local regulations and rules 5 1 2 Isolator switch The machine must be preceded by a lockable isolator switch for the electric power supply The switch must be easily accessible on a wall close to the machine The installation must conform to an...

Page 13: ...7 L1 L2 L3 N PE L1 L2 L3 N PE X50 3N PE L1 L2 L3 PE L1 L2 L3 PE X50 3 PE 5 1 4 Pre fuse requirements See section 3 TECHNICAL DATA 5 ELECTRICAL INSTALLATION USER MANUAL GETINGE DRYING CABINET S 363 13 24 Doc_6001300802 Rev C Lang_en ...

Page 14: ... pressing B 5 Start the drying operation by pressing the start stop button The LED comes on when the drying process starts Note Do not disconnect the power supply during the drying process 6 Drying is complete when the display shows 0 Note It is time to clean the filter cassette when the display alternates between and the drying time 7 Digital display of chamber temperature By pressing the two arr...

Page 15: ...uring the drying operation these blind flanges must be slid into the empty guides If only a single cassette is used all 4 blind flanges must be slid in leaving one guide uncovered 7 2 Maintenance when necessary When necessary the outside and the inside of the drying cabinet can be cleaned and disinfected with an alcohol based detergent surgical spirit or normal detergent The control panel can be c...

Page 16: ...must only be done by authorized personnel WARNING Before starting work make sure that the machine is disconnected from the electric power supply 1 004836 C A B 2 10 7 ERROR CODE 1 16 24 USER MANUAL GETINGE DRYING CABINET S 363 Doc_6001300802 Rev C Lang_en ...

Page 17: ...eaning or drying 9 Check that the filter cassette has dried completely 10 Put the cassette back into place after cleaning it N B Make sure the cassette is not turned upside down The contacts C at the back of the filter should face downwards Do not use sharp implements when dismantling 7 4 Overheating cut out WARNING Only to be carried out by authorized staff WARNING Before starting work make sure ...

Page 18: ...Danmark A S Industriparken 44 B DK 2750 Ballerup Denmark Phone 45 45 93 27 27 Fax 45 45 93 41 20 E mail getinge denmark getinge com Finland Getinge Finland AB Niittykatu 8 FI 02200 Espoo Finland Phone 35 89 6824 120 E mail getinge finland getinge com France Getinge France SAS BP 49 avenue du Canada ZA de Courtaboeuf Les Ulis FR 91942 France Phone 33 1 64 86 89 00 E mail getinge france getinge fr G...

Page 19: ...rid Spain Phone 34 916 78 26 26 E mail administracion getinge es Sweden Getinge Sverige AB P O Box 69 SE 310 44 Getinge Sweden Phone 46 10 335 30 00 E mail info getinge com Switzerland Getinge ALFA AG Weidenweg 17 4310 Rheinfelden Switzerland www getingealfa ch Phone 41 61 836 15 15 E mail info alfo ag United Kingdom Getinge UK Ltd 1 Pembroke Avenue Waterbeach Cambridge CB25 9QP United Kingdom Pho...

Page 20: ......

Page 21: ...ctions 12 ELECTRICAL INSTALLATION 12 ERROR CODE 1 15 Free standing model 10 General safety instructions 6 INSTALLATION 10 Intended use 5 INTRODUCTION 5 Isolator switch 6 12 Maintenance when necessary 15 Manual discharge damper 11 Manufacturer 5 Overheating cut out 17 Pre fuse requirements 13 Product liability 5 SAFETY INSTRUCTIONS 6 TECHNICAL DATA 8 USER MANUAL 1 Warning symbols 7 Warranty 5 Alpha...

Page 22: ......

Page 23: ......

Page 24: ...www getinge com Doc_6001300802 Rev C Lang_en ...

Reviews: