Specification 

 

The figures below are for reference only; and are based on practical operation. 
Performance may vary slightly depending on environmental conditions. 

    

Description of product 

Portable Air Conditioner/Heater 

GET Model No. 

 

GPACU12HR 

Voltage/Frequency 

 

AC 220-240V / 50Hz 

Input Power (Cooling) 

 

1400 W 

Input Power (Heating) 

 

1350 W 

Operating Cycle (Cooling) 

 

6.2 A 

Operating Cycle (Heating) 

 

6.1 A 

Cooling Capacity 

12000BTU/Hr / 3.5 kW 

 

Heating Capacity 

 

3.2 kW 

 

Dehumidifying capacity 

 

2.2 L/hour 

Coolant 

 

R-410A 

Timer 

 

24 hour 

Dimensions 

(W) X (H) X (D) 

 

50 cm X 84.5 cm X 40 cm 

Weight (N.W.) 

 

36Kg 

 

 

NOTE:- 

Waste electrical products and products containing 
refrigerants should not be disposed of with 
household waste. 
Please recycle where facilities exist. 
Check with your local authority or retailer for 
recycling advice.  

 

 

 
 

GET Plc., Key Point, 3-17, High Street, Potters Bar, Herts. EN^ 5AJ 

 

Helpline Telephone No. 0121 565 7770 

 
 

AR0853 Ed.E 

Summary of Contents for GPACU12HR

Page 1: ...USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No GPACU12HR ...

Page 2: ...CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting ...

Page 3: ...lti functional room air exchanging air processing appliance designed to offer you the functions of Air Conditioning Dehumidifying Heating and Independent Fan This manual will provide you with valuable information necessary for the proper care and maintenance for your new appliance Read these instructions fully before operating the unit and retain them for future reference If properly maintained yo...

Page 4: ...eplacement ensure that equivalent rated and approved components are used See plug replacement details below 9 IMPORTANT If this unit is sited in a room containing a fuel burning appliance the installer must ensure that the air replacement is sufficient for both the unit used as an air conditioner and the fuel burning appliance PLUG REPLACEMENT If the plug is damaged and requires replacement follow...

Page 5: ...Identification of Parts 1 Control Panel 2 Cold air outlet 3 Remote control receiver window 4 Transport handle 5 Air outlet hose 6 Evaporator air intake 7 Air intake 8 Drain port 9 Mains lead ...

Page 6: ...o allow the vent hose to reach outside the room The air intake should be a minimum distance of 50cm from any object Do not install the unit underneath desks or inside cupboards as this will restrict the operating air flow Ensure that there are no obstructions to the air intake or air outlet Ensure that the air intake is not being blocked by curtains or similar objects The end of the vent hose shou...

Page 7: ...able wall venting kit details available from the Helpline which also contains an external grille and hose to pass through the wall 1 Make a suitable size hole through the external wall to accept the hose in the wall venting kit 2 Secure the flexible ducting in the wall venting kit to the wall fitting using cable ties 3 Pass the flexible ducting through the hole in the wall from the inside 4 Fix th...

Page 8: ...o HEATING FAN legend will illuminate yellow Note In Cool Heating and Fan modes the fan speed can be set to High Medium and Low When Dehumidifier mode is selected and the room temperature is below 25 C the fan speed is automatically set to medium and cannot be altered from this setting When the room temperature is above 26 C the fan speed is adjustable Cool Mode In this mode the air is cooled and h...

Page 9: ...o select the number of hours until it is required for the machine to start up automatically The green LED will continue to flash and the display will show the time set Timer Temperature Adjust buttons In Cooling or Dehumidifying mode the temperature can be manually set by pressing the Timer Temp Adjust buttons between the limits of 16 to 32 C as shown in the display panel This cannot be done in Fa...

Page 10: ...REMOTE CONTROL UNIT ...

Page 11: ...o the supply socket Run a short while only The set temperature is close to room temperature Try lowering the set temperature Air outlet is blocked by obstacle Remove obstacle Run but not cool The door or window is open wide There is another heating appliance working in the room like heater or lamp etc The air filter is dirty Clean it Air outlet or intake is blocked Set temperature is too high Redu...

Page 12: ...ater about 40 C with a neutral detergent Rinse the filter and allow to dry Replace the filter by sliding it down into the back of the unit 2 If the appliance will not be used for a long time it is important to pull out the rubber plug from the drain port at the lower rear of the machine in order to drain the water 3 Take the batteries out of the remote controller and keep it in a safe place 4 Clea...

Page 13: ...ing 6 2 A Operating Cycle Heating 6 1 A Cooling Capacity 12000BTU Hr 3 5 kW Heating Capacity 3 2 kW Dehumidifying capacity 2 2 L hour Coolant R 410A Timer 24 hour Dimensions W X H X D 50 cm X 84 5 cm X 40 cm Weight N W 36Kg NOTE Waste electrical products and products containing refrigerants should not be disposed of with household waste Please recycle where facilities exist Check with your local a...

Reviews: