background image

 
 

THESE DEHUMIDIFIERS ARE INTENDED FOR DOMESTIC USE ONLY. 

 
SAFETY NOTES 
 

1.  Do not connect to any AC socket outlet that is damaged *. 
2.  Do not use with extension leads and multi-way adapters. 
3.  Ensure hands are not wet when inserting the plug into the power socket.    
4.  Do not use in the following locations:- 

Next to a source of fire. 
An area where oil is likely to splash. 
An area exposed to direct sunlight. 
An area where water is likely to splash.     
Near a bath, shower or a swimming pool. 
In a greenhouse. 

                      

An area where flammable gases or liquids are present. 

5.  Never insert your finger or any foreign objects into the air outlet.  Take special care to warn children of these 

dangers. 

6.  Always store the unit upright in order to maintain the compressor in a proper working condition.  If not, leave the 

unit upright for at least 24 hours before operating. 

7.  Always unplug the unit before cleaning. 
8.  Do not cover the unit or place any object on the control panel 
9.  Do not obstruct the air inlets/outlets of the appliance. 
10.  Do not allow children to play with or climb on the machine. 
11.  If a fault develops or if servicing is required, this must only be carried out be a qualified service engineer.  
12.  If the supply cord of this appliance becomes damaged, it must be replaced by a qualified engineer. 

     

13. This appliance is fitted with an approved BS 1363 13A 3 pin plug and a 13A BS 1362 fuse.  In the event of either    

      requiring replacement ensure that equivalent rated and approved components are used.  See plug replacement 
      details below.

 

 

PLUG REPLACEMENT 

If the plug is damaged and requires replacement, follow the wiring instructions supplied with the new plug. 

 

1. The green and yellow wire must be connected to the 
terminal marked with the letter E or the earth symbol. 
 
2.  The blue wire must be connected to the terminal 
marked with the letter N. 
 
3.  The brown wire must be connected to the terminal 
marked with the letter L. 
 
4.  A 13 amp plug to BS 1363 must be fitted a 13 Amp 
fuse to BS 1362. 

 

 
 
 

* For your safety and protection, this unit is earthed through the power cord plug when plugged into a matching wall 
socket.  If you are not sure whether the wall sockets in your home are properly earthed, consult a qualified electrician.  Do 
not use plug adaptors or extension cords with this unit.   

 

 
 
 
 
 
 
 
 
 

Summary of Contents for DHMD163

Page 1: ...ONS FOR PORTABLE DEHUMIDIFIERS 16 LITRE MODEL NO DHMD163 20 LITRE MODEL NO DHMD203 THANK YOU FOR CHOOSING YOUR NEW DEHUMIDIFIER BEFORE USING THE UNIT READ THESE INSTRUCTIONS FULLY AND RETAIN THEM FOR FUTURE REFERENCE ...

Page 2: ...o play with or climb on the machine 11 If a fault develops or if servicing is required this must only be carried out be a qualified service engineer 12 If the supply cord of this appliance becomes damaged it must be replaced by a qualified engineer 13 This appliance is fitted with an approved BS 1363 13A 3 pin plug and a 13A BS 1362 fuse In the event of either requiring replacement ensure that equ...

Page 3: ...ng air in the room Timer setting in hours 01 to 12 This symbol shows when machine is defrosting Machine stopped due to full water tank Fan on LOW speed Fan on HIGH speed Tank Full Indicator Power Button Timer Button LED Display Ambient Temperature Ambient Humidity Fan Speed Indicator Set Humidity Level indicator Humidity Level Setting Buttons Fan Speed Button ...

Page 4: ... machine the compressor within the machine will start up and any moisture in the air drawn through the machine by the fan will form as water droplets on the condenser within the machine These water droplets will eventually collect in the water tank in the front of the machine 5 When the machine brings the humidity level in the room down to the level set on the machine the compressor will switch of...

Page 5: ...ted If the temperature remains below 5 C the machine should be switched off CONTINUOUS DRAINING OPTION When the dehumidifier is used in a situation where it is neither desirable nor convenient to keep having to empty the water tank there is a facility to enable the unit to be continuously drained This will allow the unit to be run continually without the need to periodically empty the water tank T...

Page 6: ...floor as it could cause noise vibration and spillage of water Keep the unit at least 20cm from a wall to dissipate the heat Clothes may be hung no closer than 50cm above the machine It is dangerous to put any object into the intake and outlet grilles of the machine Closing doors and windows will maximise the efficiency of the unit Do not expose the unit to any sources of heat When moving or storin...

Page 7: ...ean the filter by means of a vacuum cleaner or wash it with clean water and dry using a cloth 3 Replace the filter by engaging the bottom edge in the slots provided in the body and push the top edge inwards until it clips into place TROUBLESHOOTING If you have any minor problems with the dehumidifier check the items mentioned below before contacting the helpline Problem Possible Cause Solution Bot...

Page 8: ... D 30 C 80 RH 20 L D 30 C 80 RH POWER INPUT 300W 350W REFRIGERANT R 134a 190g R 134a 210g PRESSURE SUCTION 12kg cm 12kg cm PRESSURE DISCHARGE 24kg cm 24kg cm OVERALL SIZE H x W x D 58 2cm x 36 2cm x 27 0cm 58 2cm x 36 2cm x 27 0cm WEIGHT 14 5kg 15 0kg OPERATING TEMPERATURE 5 C to 35 C 5 C to 35 C NOTE Waste electrical products and products containing refrigerants should not be disposed of with hou...

Reviews: