7
ORGS 111
Outputs for control circuit
2 volt-free change-over contacts,
8 A 250 V AC / 30 V DC cos
ϕ
= 1
De-energizing delay: 3 sec.
Provide inductive loads with RC combinations according to manufacturer's specification to ensure
interference suppression.
Indicators and adjusters
2 red LEDs indicating "Electrode submerged" and "Output relay energized" (no ingress of oil)
1 four-pole code switch for selecting the response sensitivity
Electrical connection
2 cable gland with integrated cable clamp M20 x 1.5
1 five-pole screw-type terminal strip, detachable, conductor size 1.5 mm
2
Protection
IP 65 to DIN EN 60529
Max. admissible ambient temperature
Max. 70 °C
Storage and transport temperature
– 40 up to + 80 °C
Certification
Marine applications
Det Norske Veritas / Germanischer Lloyd
Bureau Veritas
Lloyds Register
Technical data
Scope of supply
ORGS 112
1 Oil detector & alarm ORGS 11-2, PN 6
1 Measuring electrode ORGS 11-1 (mounted)
2 Sealing plugs for cable entry
1 Installation manual
continued