background image

6

3.

 General Description of Use

Tool Changing

The Gesswein Power Hand Angle Rotary 

Handpiece uses a quick-tool-release mech-

anism that allows for rapid tool changes. To 

operate, turn the Collet Release Ring coun-

terclockwise toward the arrow pointing to the 

“R” or release position (see fig. 2). When in 

the full “R” position, the Collet Release Ring 

will make a click sound; the collet is then fully 

open and ready to accept a tool.
To secure the tool, turn the Collet Release 

Ring toward the “S” or secure position. 

Again, a click sound will be heard, indicat-

ing the collet is fully closed and the tool is 

secure. 
When changing tools, be sure that the hand-

piece motor is not running. If you attempt a 

tool change under this condition, the motor 

will be stalled and damage will occur.

Collet Removal

The Angle Rotary Handpieces can accept 

many different size collets (see Specifications). 

Standard sizes are 

3

32

" (2.35mm) and 

1

8

(3.2mm).
To change collets, turn the Collet Release Ring 

to the full “R” position and remove the tool in 

the collet. Hold the collet between the thumb 

and forefinger and turn in a counterclockwise 

direction until the collet is removed (see fig. 

3). Insert the new collet and reverse the pro-

cedure. It is best to always tighten a replaced 

collet by hand using the Collet Wrench (#510-

0180), securing until just tight. 

Release

Secure

Fig. 2

Secure

Release

S

R

Fig. 3