25
GB
11. Repairs
Repairs under warranty are carried out by the manufacturer. Repairs outside the warranty pe-
riod should only be carried out by skilled technical personnel. Failure to observe the assembly
and setting procedures and operation by non-skilled personnel may result in serious damage to
the riveting tool. In case of doubt, always send in the device to the manufacturer.
12. Troubleshooting
12.1 Blind rivet is not set
Cause
Corrective measures
Jaws soiled
Clean and oil sliding surfaces (see 10.1)
Jaws worn
Replace (see 10.1)
Insufficient compressed air
See operating pressure (see 3)
Cause
Corrective measures
Wrong nosepiece used
Exchange according to table (see 6)
Nosepiece worn
Replace
Spent mandrel jammed in jaws
Clean jaws and jaw housing and oil sliding
surfaces; replace if worn (see 10.1)
Spent mandrel container full
Empty (see 9)
12.2 Spent mandrel is not conveyed automatically into the container