background image

11

   

 

D1

D2

Parameter

D3

D4

Preset option      Options or values  

C

1

Motor turning direction and limit
switches configuration

0

1

x

0

2

 

3

Type of gate

0

2

x

Sliding gate

4

Opening safety device (photocell or
strip)

0

0

x

Device not installed

1

0

Device without testing

1

1

Device with testing

5

Closing safety device (photocell or
strip)
Closing photocell with 

C520

 or 

C521

,

also prevents the start of gate opening

0

0

x

Device not installed

1

0

Device without testing

1

1

Device with testing

2

0

Device without testing

2

1

Device with testing

7

Encoder and limit switches

(when using external limit switches,
connect them to the corresponding
terminals of the control board)

0

0

No encoder or limit switches

0

2

x

With internal limit switches

0

4

With encoder and internal limit switches

0

6

With external limit switches

0

7

With encoder and external limit switches

8

Radio receiver

0

1

RSD card (frame, not decoder)

0

2

x

Twin-channel decoder card

9

Safety strip type

0

1

x

Contact edge

0

2

Resistive edge

A

Slowdown

0

0

No slowdown

0

1

x

Slowdown in opening and closing

0

2

Slowdown in opening

0

3

Slowdown in closing

P

1

T o t a l   o p e n i n g   r a d i o   c o d e
programming

o

ç

2

P e d e s t r i a n   o p e n i n g   r a d i o   c o d e
programming

o

ç

3

Gate open/close programming

o

ç

F

1

Key command using ST1 and ST2
pushbuttons

0

0

ST1 and ST2 without effect, key commands
are made by radio (channel 1: total
opening-closing, channel 2: pedestrian
opening-closing)

0

1

x

ST1 total opening-closing, ST2 pedestrian
opening-closing

0

2

ST1 total opening, ST2 total closing

0

3

Dead-man mode

0

4

Dead-man mode in closing

2

Operation mode (step-by-step or
automatic) and stand-by time (in
seconds) in automatic mode

0

...

5

.

0

...

9

00

00

: step-by-step mode 

01

: automatic mode and stand-by time 1

second;  ...

59

: automatic mode and stand-by time 59

sec.; 

1

.

0

:  1 min. 0 sec.; ...;  maximum 4 minutes

3

Pedestrian opening

0

...

9

0

...

9

40

00

: Pedestrian opening is not carried out

01

: 1% of total opening

12

: 12% of total opening

99

: 99% of total opening (equivalent to

100%)

4

Pedestrian closing mode (step-by-step
or automatic) and stand-by time (in
seconds) in automatic mode

0

...

5

.

0

...

9

00

00

: step-by-step mode 

01

: automatic mode and stand-by time 1

second;  ...

59

: automatic mode and stand-by time 59

sec.; 

1

.

0

:  1 min. 0 sec.; ...;  maximum 4 minutes

Complete programming chart