background image

7

TORO-I

Quick installation and programming guide

English

   

 

WARNING

This quick guide is a summary of the complete installation manual. The manual contains safety warnings and
other explanations which must be taken into account. The most recent versions of this guide and the
installation manual are available at the "Downloads" section on Erreka's website. 

http://www.erreka-automation.com

The options and functions described in this guide apply for the firmware version indicated on the circuit. The
firmware, as part of a process of continuous improvement, is subject to new functionalities or upgrades being
included as a result of new versions which are not necessarily compatible with previous ones. For this reason,
some options or functions may differ or be unavailable if your firmware is older than shown in this guide.

E295A

SG.C

SG.C

SG.C

SG.C

SG.A

C295B

Elements of the complete installation

Assembly levels (mm)

Photocells

SG.A

: opening photocell,

enable: 

C410

enable testing: 

C411

SG.C:

closing photocell,
enable: 

C510

enable testing: 

C511

enable with opening 
disabled: 

C520

enable testing with 
opening disabled: 

C521

ELECTRICAL WIRING:

Element

Nº wires x section

Maximum 

length

A: Main power supply

3x1.5mm

2

30m

B: Flashing light

2x0.5mm

2

20m

C: Photocells (Tx / Rx)

2x0.5mm

2

 / 4x0.5mm

2

30m

D: Pushbutton/wall key

2x0.5mm

2

50m

E: Antenna

Coaxial cable 50

(RG-58/U)

5m