Declaration

Manufacturer's name and address or his 
 authorized representative in the Community

Nilfi sk-Advance A/S
Industrikvarteret
9560 Hadsund
Denmark

Name of the person responsible for the 
 technical documentation

Anton Sørensen, General Manager of Technical Operations EAPC

Description of the equipment:
  Equipment name
  Model
  Rated output voltage
  Rated frequency  

High pressure washer
Gerni
Classic 100.2 / Classic 110.2
AC 230 V
50 Hz

Measured sound pressure level

78 dB(A)

Guaranteed sound power level

80 dB(A)

Declaration

The equipment refer in this document fulfi ls all the requirements of 
the Directive :

Machine Directive 

2006/42/EC

Low-voltage Directive 

2006/95/EEC

EMC Directive    

 2004/108/EEC

Outdoor Noise Directive  

 2000/14/EC

EN ISO 12100-1, EN ISO 12100-2, EN 60335-2-79
EN 55014-1 (2006), EN 55014-2 (2001), EN 61000-3-2 (2006)

Place and date of the  declaration

Hadsund, October 1, 2008

Signature

9 Main 

Technical 

Data

Type

Classic 100.2

Classic 110.2

Rated pressure

bar/MPa

70/7.0

75/7.5

Permissible pressure

bar/MPa

max. 100/10.0

max. 110/11.0

Rated flow

l/min

5.3

5.2

Rated input

kW

1.3

1.4

Rated voltage

V

230

230

Max. water temperature

°C

40

40

Inlet pressure

bar/MPa

0.15-10/0.015/1.0

0.15-10/0.015/1.0

Sound pressure level 

dB(A)

78

78

Guaranteed sound power level 

dB(A)

80

80

Vibration according to ISO 5349  m/s

2

max. 2.5

max. 2.5

10 Declaration

Summary of Contents for Classic 100.2

Page 1: ...128303187 01 2009 Classic 100 2 Classic 110 2 User Guide Classic 100 2 Classic 110 2 ...

Page 2: ...Printed in China Copyright 2009 Gerni ...

Page 3: ... Children should be su pervised to ensure that they do not play with the appliance Before starting up your machine please check it carefully for any defects If you find any do not start up your machine and con tact your Gerni distributor Especially check The insulation of the electric cable should be faultless and without any cracks If the electric cable is damaged an authorized Gerni distributor ...

Page 4: ...ll be made by a certified elec trician and comply with IEC 364 It is recommended that the electric supply to this appli ance should include either a residual current device that will interrupt the supply if the leakage current to earth ex ceeds 30 mA for 30 ms Water connection Connection to the public mains according to regula tions Inlet hose can be connected to the water mains with a max inlet p...

Page 5: ...ersonal injuries 2 2 Operation elements and model survey See illustration at the end of this manual 1 Start stop switch 2 Water inlet with filter 2a 3 High pressure connection 4 High pressure hose 5 Electric cable 6 Click Clean spray lance 7 Spray gun with lock 7a 8 Click Clean Tornado nozzle 9 Click Clean Powerspeed nozzle 10 Foam sprayer 11 Nozzle cleaning tool 12 Lance and nozzle holder 13 Mode...

Page 6: ...er impurities as these will damage the pump valves Caution Failure to fit the filter will invalidate the guarantee 3 1 Mounting of trolley handle models with trol ley handle 3 3 Mounting of high pres sure hose on spray gun 1 Attach the high pressure hose 4 to the spray gun 7 Detach the high pressure hose by pressing the pawl A 1 Place the trolley handle on the machine 2 Secure the handle by mount ...

Page 7: ...n 7 and screw it on Note The spray lance 6 has a built in low pres sure nozzle that can be used for flushing away dirt 2 Attach the nozzle Warning When attaching the Click Clean nozzles the pawl on the side of the spray lance 6 should come out again Note The foam sprayer 10 features a swivel lock which must be positioned in the hole in the Click Clean spray lance 6 Press the pawl to detach the Cli...

Page 8: ...quate ventila tion Note If the ma chine is left or not used for 5 min utes it must be switched off on the start stop switch O 1 1 Press the start stop switch O 2 Disconnect the electrical plug from the socket 3 Shut off the water supply and activate the trigger to relieve the machine of pressure 4 Lock the spray gun 7a When releasing the trigger of the spray gun the machine automatically stops The...

Page 9: ...toring as follows 1 Stop the machine press the start stop switch O 1 and detach water hose and ac cessory 2 Restart the machine and activate the trigger Let the machine run until no more water runs through the spray gun 3 Stop the machine unplug and wind up hose and cable 4 Place spray handle nozzles and other accessories in the holders of the machine Should the machine by mistake be frozen it wil...

Page 10: ...r inlet filter regularly once a month or more frequently according to use Carefully loosen the filter with a screwdriver and clean it Check that it is intact before re mount ing it The inlet filter must always be fitted inside the water inlet pipe to filter out sand limestone and other impurities as they will damage the pump valves CAUTION Failure to fit the filter will invalidate the guarantee 6 ...

Page 11: ...ents The machine should be kept clean so as to let cooling air pass freely through the ma chine vents To ensure an easy connec tion and that o rings do not dry up the couplings should be greased regularly 6 4 Greasing of couplings ...

Page 12: ...own Nozzle partially blocked Clean the nozzle see section 6 2 Fuse blows Fuse too small Change to an installation higher than the amp consumption of the machine You may try without the extension cable Machine pulsating Air in inlet hose pump Allow machine to run with open trigger until regular working pressure resumes Inadequate supply of Check that the water supply corresponds to mains water spec...

Page 13: ...red by the guarantee that the directions of this instruction manual have been thoroughly observed that repair has not been carried out or attempted by other than Gerni trained service staff that only original accessories have been applied that the product has not been exposed to abuse such as knocks bumps or frost that only water without any impurities has been used that the high pressure washer h...

Page 14: ...ll the requirements of the Directive Machine Directive 2006 42 EC Low voltage Directive 2006 95 EEC EMC Directive 2004 108 EEC Outdoor Noise Directive 2000 14 EC EN ISO 12100 1 EN ISO 12100 2 EN 60335 2 79 EN 55014 1 2006 EN 55014 2 2001 EN 61000 3 2 2006 Place and date of the declaration Hadsund October 1 2008 Signature 9 Main Technical Data Type Classic 100 2 Classic 110 2 Rated pressure bar MPa...

Page 15: ......

Page 16: ......

Page 17: ......

Page 18: ......

Page 19: ......

Page 20: ...Nilfisk Advance Pty LTd 48 Egerton St Silverwater NSW 2128 Phone 1300 556 710 ...

Reviews: