German pool SH-09 Operating Instructions Manual Download Page 20

1.

2. Select a position where the condensing water can be easily drained out, and the place

is easily connected for outdoor unit.

4. Can select the place where is strong enough to withstand the full weight and vibration of

the unit. And will not increase the noise.

5.

6.

7.

8. Make sure that the indoor unit installation should accord with installation dimension 

diagram requirements. 

3. Select a location where the children can not reach.

1. The unit installation work must be done by qualified personnel according to the local

rules and this manual.

2. Before installation, please contact with local authorized maintenance center, if unit is

not installed by the authorized maintenance center, the malfunction may not solved,

due to discommodious contacts.

3. W

4

.

the appliance must be positioned so that the plug is accessible

5

.

After pull out the power plug then make the appliance operation again

to avoid the 

icing of outdoor unit damage axial flow fan

should electrify the appliance but not 

operation for 4 hours for warm-up purpose(only for 

SH-09

hen removing the unit to the other place, please firstly contact with the authorized

Maintenance Center in the local area.

Notices for installation

Important Notices

Basic Requirements For Installation Position

Install in the following place may cause malfunction. If it is unavoidable contact with 

service center please:

Place where strong heat sources, vapors, flammable gas or volatile object are emitted.

Place where high-frequency waves are generated by radio equipment, welders and 

medical equipment.

Place where a lot of salinities such as coast exists.

Place where the oil (machine oil) is contained in the air.

Place where a sulfured gas such as the hot spring zones is generated.

Other place with special circumstance.

Indoor Unit Installation Position Selection

The air inlet and outlet vent should be far from the obstruction, make sure that the air

can be blown through the whole room.

Be sure to leave enough space to allow access for routine maintenance.The height of the

installed location should be 250cm or more from the floor.

Select a place about 1m or more away from TVset or any other electric appliances.

Select a place where the filter can be easily taken out.

.

Do not use the unit in the immediate surroundings of a laundry a bath a shower or a

swimming pool.

9

17

model

Summary of Contents for SH-09

Page 1: ......

Page 2: ......

Page 3: ...t as unsorted municipal waste Collection of such waste separately for special treatment is necessary The products in this manual may be different with the real one according to different models some m...

Page 4: ...n for a long time while operating the air conditioner It can decrease the air conditioning capacity Don t block the air intake or outlet vents of both the outdoor and indoor units It can decrease the...

Page 5: ...ver of left right direction Louver of upward downward direction Don t insert your hands or stick into the air intake or outlet vents Otherwise it will cause accident Don t blow the wind to animals and...

Page 6: ...ty will increase or decrease by outdoor ambient temperature If the unit is running in COOL mode and in low temperature there will be frost formed on the heat exchanger when indoor heat exchanger tempe...

Page 7: ...temperature range Maximum cooling Maximum heating Indoor sideDB WB o C Outdoor sideDB WB o C 32 23 27 43 26 24 18 The operating temperature range outdoor temperature for cooling only unit is 18 43 fo...

Page 8: ...it Air in Air out Outdoor unit Wireless remote control Air in Air out Power cable Remote control Front panel Filter Guide louver Wall pipe Bind tape Connection wire Drainage pipe Cool Dry Fan Heat Set...

Page 9: ...rature setting Press it to decrease temperature setting FAN Press it to set swing angle TIMER ON TIMER OFF CLOCK Blow page 9 TEMP page 9 TURBO page 9 SLEEP page 9 Press it to turn on off the light LIG...

Page 10: ...ation mode icon AUTO COOL DRY FAN or HEAT is only for heat pump models will show 15 is displayed when pressing the up down swing button Press this button again to clear the display 18 Up down swing ic...

Page 11: ...that goes from AUTO to then back to Auto Auto Low speed Medium speed High speed Press this button to set up down swing angle which circularly changes as below OFF 1 2 3 4 5 6 Operation of Remote Contr...

Page 12: ...els SLEEP Press this button to go into the SLEEP operation mode Press it again to cancel this function This function is available in COOL HEAT Only for models with heating function or DRY mode to main...

Page 13: ...ote controller will not be used for a long time please Otherwise it may cause malfunction remove batteries to prevent batteries from leaking The operation should be performed in its receiving range It...

Page 14: ...ght off If cancel the light function the mark will disap per on the remote controller screen by pressing this button In which case the displayer indicator light will be off if the AC receives this sig...

Page 15: ...d hurt your fingers Take down the air filter At the slot of surface panel to open an angle pull the air filter downward and take it out please see the Fig 4 a b To clean the dust adhering to the filte...

Page 16: ...ct the dealer Clean and care Check before use Check that whether ground wire is properly connected or not Maintain after use Turn main power off Clean the filter and indoor and outdoor units bodies Cl...

Page 17: ...em still has so need to clean air conditioner Please contact with the authorized maintenance center Sound of water flow can be heard during the operation The air conditioner is started when it is runn...

Page 18: ...in its receiving range Or obstructed To check the voltage in wireless remote control inside is charged otherwise to replace the batteries Whether the wireless remote control is damaged If water leaka...

Page 19: ...mething into unit There is an abnormal heat in power supply cord and power plug Stop running and pull out of the plug In HEAT mode when the temperature of indoor heat exchanger is very low that will s...

Page 20: ...t to the other place please firstly contact with the authorized Maintenance Center in the local area Notices for installation Important Notices Basic Requirements For Installation Position Install in...

Page 21: ...ional The air switch must have the functions of magnetic tripping and heat tripping in order to protect the short circuit and overloading 6 Notices for installation Safety Requirements For Electric Ap...

Page 22: ...able earthing terminal Please don t connect the earthing wire with the following place Tap water pipe Gas pipe Contamination pipe Other places that professional personnel consider them unreliable 5 In...

Page 23: ...Air outlet side Space to the floor Above Above Above 15cm Above Above Space to the obstruction Air outlet side Space to the wall Air inlet side Above Above Above The dimensions of the space necessary...

Page 24: ...pe 1 For well draining the drain hose should be placed at a downward slant 2 Do not wrench or bend the drain hose or flood its end by water 3 When the long drainage hose passing through indoor should...

Page 25: ...off the tailings 1 and tailings 2 when routing both the wiring and piping Take out the piping from body case wrap the piping electric wire water pipe with tape and pull them through the piping hole As...

Page 26: ...te Take off cord anchorage Connect and fix power connect cord for heat pump type connect and fix power connect cord and signal control wire to terminal block Fix the power connection cable with cord a...

Page 27: ...e It may cause electric malfunction or damage the part Is the electric wiring and piping connection installed correctly and securely It may cause electric malfunction or damage the part Has the unit b...

Page 28: ...tion As for silver ion filter it is invalid when its surface becomes according to the installation instruction Pay special attention to that silver Take out the healthy filter before cleaning and rein...

Page 29: ...dditional refrigerant charging amount on the 1 Additional refrigerant charging amount prolonged length of liquid pipe additional refrigerant charging amount per meter 2 When the length of connection p...

Page 30: ...Diameter of connection pipe mm Indoor unit throttle Outdoor unit throttle Liquid pipe Gas pipe Cooling only cooling and heating g m Cooling only g m Cooling and heating g m 6 9 5 or 12 20 15 20 6 or 9...

Page 31: ......

Page 32: ...d without prior authorization from German Pool violators will be prosecuted Hong Kong Sole Agent China Sole Agent 116 2 4 Room 2 4 Upper G F Newport Centre 116 Ma Tau Kok Road Tokwawan Kowloon Tel 852...

Reviews: