German pool PAC-215 User Manual Download Page 10

P.19

P.18

DRY mode

Ideal to reduce room humidity (spring and autumn, damp rooms, rainy 

periods, etc).

In dry mode, the appliance should be prepared in the same way as cool 

mode, with the air exhaust hose attached to enable the moisture to be 

discharged outside.
To set this mode correctly:
• Press the       button a number of times until the        symbol appears.
• Select the required fan speed by pressing the        button.

Three speeds are available:

Maximum speed: to achieve the best dehumidifying effect.

Medium speed: can reduce noise levels but still maintains a better dehumidify effect.

Low speed: for silent operation but lowers the dehumidifying effect relatively.

SWING function

This function is useful for select the up/down swing of air Delivery. 

To set this function correctly:
• Select the operating mode (cool, heat, dry, fan) as described above.

• Press the        button several times, the deflector will stop at different positions or swing continuously.

Swing

The deflector position

SLEEP mode function

This function is useful for the night as it gradually reduces operation of the appliance. 
To set this function correctly:
• Select the cool or heat mode as described above.
    Press the         button. The appliance operates in the previously selected mode.
• When you choose the sleep function, the screen will be dimmed .

The SLEEP function maintains the room at optimum temperature without excessive fluctuations in 

either temperature or humidity with silent operation.

Fan speed is always at Low, while room temperature and humidity vary gradually to ensure optimum 

comfort.
When in COOL mode, the selected temperature will increase by 1°C(1°F) per hour in a 2 hour period. 

This new temperature will be maintained for the next 6 hours before the appliance shuts off. 

When in HEAT mode, the selected temperature will decrease by 1°C(1°F) per hour in a 3 hour period. 

This new temperature will be maintained for the next 5 hours before the appliance shuts off.

The SLEEP function can be canceled at any time during operation by pressing the “Sleep”, “Mode” or 

“Fan Speed” button.

In FAN or DRY mode, SLEEP mode function cannot be set.

Switch the unit of temperature

When the appliance is in standby mode, press the °C/°F button, then you can change the unit of 

temperature.
For example:

Before change, in cool mode, the screen display looks like fig9.
After change, in cool mode, the screen display looks like fig10.

Fig 9

Fig 10

Operating Instructions

Operating Instructions

Note: Under dry mode the temperature cannot be adjusted, only wind speed can be adjusted.
Note: When indoor temperature is ≤16°C, compressor unit will not activate and dry mode will not be 

available.  

Summary of Contents for PAC-215

Page 1: ...read these instructions and warranty information carefully before use and keep them handy for future reference Online Warranty Registration P o r t a b l e A i r C o n d i t i o n e r PAC 215 U S E R...

Page 2: ...ctions 8 Operating Instructions 11 Care and Maintenance 23 Troubleshooting 24 Technical Specification 26 Environment and Recycling 26 Warranty Terms Conditions 51 Please register your warranty informa...

Page 3: ...ounding tab from this plug The unit should be used or stored in such a way that it is protected from moisture e g condensation splashed water etc Unplug unit immediately if this occurs Always transpor...

Page 4: ...hange the existing receptacle in accor dance with the National Electrical Code and applicable local codes and ordinances The third ground prong should not under any circumstances be cut or removed Nev...

Page 5: ...fix the hose outlet into the window slider kit and seal Fig 5 6 Cut on opposite side of hole Your window slider kit has been designed to fit most standard vertical and horizontal window applica tions...

Page 6: ...inlet or outlet of the unit Allow at least 30cm of space away from the wall for efficient air conditioning The hose can be extended but it is optimized when the hose is at minimum length Also make su...

Page 7: ...dium speed reduces noise levels but still maintains a good level of comfort Low speed for silent operation Water is removed from the air and collected in the tank When the tank is full the appliance s...

Page 8: ...button Timer button Unit Switch button Point the remote control at the receiver on the appliance The remote control must be no more than 7 meters away from the appliance without obstacles between the...

Page 9: ...noise levels but still maintains a good level of comfort Low speed for silent operation HEAT mode Water is removed from the air and collected in the tank When the tank is full the appliance shuts dow...

Page 10: ...selected mode When you choose the sleep function the screen will be dimmed The SLEEP function maintains the room at optimum temperature without excessive fluctuations in either temperature or humidit...

Page 11: ...6 When installing the appliance semi permanently you should leave a door slightly open as little as 1 cm to guarantee ventilation Protect the room from direct exposure to the sun by partially closing...

Page 12: ...h Never wash the appliance with water It could be dangerous Never use petrol alcohol or solvents to clean the appliance Never spray insecticide liquids or similar Use a vacuum cleaner to remove dust a...

Page 13: ...turned off Wait This delay is part of nor mal operation The following message appears on the display The appliance has a self diagnosis system to identify a number of malfunctions See the SELF DIAGNOS...

Page 14: ...0g H 715mm W 440mm D 355mm Important information for correct disposal of the product in accordance with EC Directive 2012 19 EU Environment Recycling At the end of its working life the product must no...

Page 15: ...P 29 P 28 8 8 6 110 50 RH80...

Page 16: ...P 31 P 30 1 2 3 4 5 6 7 8 9 10 11 4 1 2 3 1 2 5 4 3 6 7 8 9 10 11 1 1 1 MODE FAN TIMER SWING SLEEP ON OFF 1 12 30 1 1 2 2 3 3 4 4 5 6...

Page 17: ...P 33 P 32 5 6 30cm 30cm 30cm 30 1 A B C D 2 B C A 3...

Page 18: ...P 35 P 34 1 2 3 4 5 1 2 3 4 5 6 18 32 64 90 24 27 75 81 13 27 55 81 ON OFF MODE FAN 1 2 3 4 5 1 3 4 5 6 2...

Page 19: ...P 37 P 36 20 7 8 7 8 16 C...

Page 20: ...P 39 P 38 7 1 2 7m MODE FAN TIMER SWING SLEEP ON OFF 18 32 64 90 24 27 75 81 13 27 55 81 CR2025...

Page 21: ...P 41 P 40 16 C...

Page 22: ...P 43 P 42 2 1 1 6 9 10 9 10 24 1 24 11 5 12 13 5 14 11 12 13 14 15 3 1 C 1 F 5...

Page 23: ...P 45 P 44 16 1 17 18 19 1 2 3 4 5 6 16 17 18 20 1 2 3 1 2 12 7mm 4 5 21 22 19 20 21 22...

Page 24: ...P 47 P 46 40 104 27 27 23 24 25 26 23 24 25 26...

Page 25: ...P 49 P 48 3 30 www germanpool com 30 C RH80 PAC 215 1 4000 BTU hr 10 000 BTU hr 1 600W 1 450W 220 240V 50Hz 2 1MPa 4 2MPa 32kg 3 2L h R410A 500g H 715mm W 440mm D 355mm EC 2012 19 EU...

Page 26: ...at its discretion repair or replace any defective part 5 This warranty will be void if there is any transfer of ownership from the original purchaser 1 2 3 4 5 Serial No Purchased From Invoice No Pur...

Page 27: ...Fax 86 757 2980 8318 8th Xinxiang Road Wusha Industrial Park Daliang Shunde Foshan Guangdong 3 F Edificio Industrial Pou Fung 145 Rua de Francisco Xavier Pereira Macau Tel 853 2875 2699 Fax 853 2875 2...

Reviews: