Installation Instructions
P.14
The installation comes under the exclusive responsibility of a certified technician.
The installer is held to respect the legislation and the standards enforced in his home country.
How to stick the gasket:
The gasket supplied with the hob avoids all infiltration of liquids into the cabinet.
His installation has to be done carefully, in conformity of the following drawing.
Stick the gasket
②
two millimeters from the external
edge of the glass, after removing the protection sheet
③
.
-
Ensure that there is a distance of 55 mm between the hob and the wall or sides.
-
The hobs are classified as “Y” class for heat protection. Ideally the hob should be installed with plenty of
space on either side. There may be a wall at the rear and tall units or a wall at one side.
On the other side,
however, no unit or divider must stand higher than the hob.
-
The piece of furniture or the support in which the hob will be fitted, as well as the edges of furniture, the
laminate coatings and the glue used to fix them, must be able to resist temperatures of up to 100 °C.
- The mural rods of edge must be heat-resistant.
- Do not install the hob to the top of a not ventilated oven or a dishwasher.
- Guarantee
under the bottom of the hob
a min. space of
≥
110 mm
to ensure a good air circulation of the
electronic device.
-
If a drawer is placed under the cooktop, avoid to put into this drawer flammable objects (for example: sprays)
or not heat-resistant objects.
- Materials which are often used to make worktops resistant in contact with water. To protect the cutout edges,
apply a coat of varnish or special sealant. Particular care must be given to applying the adhesive foam rubber
gasket supplied with the hob to prevent any leakage into the supporting furniture. This gasket guarantees a
correct seal when used in conjunction with smooth work top surfaces.
-
The safety gap between the hob and the cooker hood (air hood) placed above must respect the indications of
the hood manufacturer. In case of absence of instructions respect a distance minimum of 760 mm.
- The connection cord should be subjected, after installing, with no mechanical constraint, such for example of
the fact of the drawer.
Fitting - installing:
The cutout sizes are:
Cutout size
Glass panel size
Model
Height
Width
Depth
Width
Depth
Thickness
DIC-146DB
≥
110mm
≥
710mm
≥
410mm
730mm
430mm
4mm
Summary of Contents for DIH-146DB
Page 16: ...請即進行保用登記 有關保用條款細則 請看本說明書最後一頁 ...
Page 30: ...P 30 Notes ...