Page 1: ...250 ELC Instruction Manual From Version 1 1 email service glp de Internet http www glp de ...

Page 2: ...GLP German Light Production V2 1 2 ...

Page 3: ...es 6 3 Selecting Address Basic Functions 7 3 1 Adjust the DMX Address 7 3 2 Special Function 8 3 2 1 Sound function 8 3 2 2 Standalone Function 8 3 2 3 Reset 8 3 2 4 Switch off Lamp 8 4 Channel selection Overview table 9 5 Change the Lamp 12 5 1 Safety rules 12 5 2 How to change the lamp 12 6 Maintenance the MAX 13 6 1 Optical System 13 6 2 Cleaning the Fans 13 7 Technical Data Overview 14 ...

Page 4: ...GLP German Light Production V2 1 4 1 Introduction Illustration 1 1 ...

Page 5: ...3 Unplug the M Ma ax x from the AC outlet before any service 4 Wait at least 30 minutes after disconnecting the AC before you open the M Ma ax x Please do not touch the Bulb unless you are absolutely sure it is cold Danger of BURNING 5 For safe operation follow the Installation guide described in chapter 2 Operating the M Ma ax x without Safety cables or clamps hooks can increase the risk of an ac...

Page 6: ...cumstance 2 2 Secure the Max Use always safety wires to secure the M Ma ax x connect them with the base plate see Drawing 1 1 Chapter 1 and check for tight fit 2 3 Connectors 2 3 1 AC Connector 230 120 Volt 50 60 Hz Please see printing on the case for the right Power supply 2 3 2 DMX DMX 512 Standard input output Please see printing on the case for the right Pin usage 2 4 Fuses The M Ma ax x elect...

Page 7: ... 1 1 1 1 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3 4 4 4 4 4 4 4 4 5 5 5 5 5 5 5 5 6 6 6 6 6 6 6 6 7 7 7 7 7 7 7 7 9 9 9 9 9 9 9 9 8 8 8 8 8 8 8 8 10 10 10 10 10 10 10 10 ON ON ON ON ON ON ON ON OFF OFF OFF OFF OFF OFF OFF OFF Address max 1 max 2 max 3 max 4 max 5 max 6 max 7 max 8 DMX Address 0 DMX Address 8 DMX Address 16 DMX Address 24 DMX Address 32 DMX Address 40 DMX Address 48 DMX Address 56 ...

Page 8: ...ing more than one M Ma ax x in a line set the Dip switches of all others connected units to OFF 1 2 3 4 5 6 7 9 8 10 ON OFF Address 3 2 3 Reset All functions will Reset and move to zero position 1 2 3 4 5 6 7 9 8 10 ON OFF Address 3 2 4 Switch off Lamp If the channels 3 Speed Arm 4 Speed Head and 8 Shutter on M Ma ax x zero at the same time the lamp of the M Ma ax x will switch off immediately Any...

Page 9: ...s min Rotation left 128 143 80 8F 51 56 Pos Max Rotation left 144 159 90 9F 57 62 Pos min Rotation right 160 175 A0 AF 63 68 Pos Max Rotation right 176 191 B0 BF 69 75 Rotation left Rotation left 192 207 C0 CF 76 81 Rotation right Rotation right 208 215 D0 D7 82 84 Rotation left Rotation right 216 231 DA E7 85 90 Rotation right Rotation left 232 254 E8 FE 91 99 Reset all functions 255 FF 100 6 Col...

Page 10: ...124 127 7C 7F 49 pink 310 128 131 80 83 50 Halfcolor 17 132 135 84 87 52 yellow 603 136 139 88 8B 54 Halfcolor 18 140 143 8C 8F 55 UV blue 108 144 147 90 93 57 Halfcolor 19 148 151 94 97 58 red 301 152 155 98 9B 60 Halfcolor 20 156 159 9C 9F 61 open no filter 160 175 A0 AF 62 68 Rotation 1 fast slow 176 208 B0 D0 69 81 Rotation stop 209 221 D1 DF 82 86 Rotation 2 slow fast 222 255 E0 FF 87 100 7 G...

Page 11: ... stop 209 255 D1 FF 82 100 8 Shutter Shutter closed 1 0 7 0 7 2 Shutter open 8 15 8 F 5 Shutter closed 2 16 23 10 17 8 Shutter frequency high low 24 127 18 7F 9 50 Shutter open color gobo speed slow fast 128 255 80 FF 51 100 Lamp off After 2 min if Shutter close or Shutter close 2 0 7 or 16 23 0 7 or 10 17 0 2 or 5 8 Lamp off Immediately if Shutter close 1 and Speed Pan Tilt 0 Shutter 0 7 and Spee...

Page 12: ... minutes Don t touch lamp with bare fingers Close the M Ma ax x before you connect the AC power 5 2 How to change the lamp Please look at Picture1 1 1 Unscrew knurled knob on the Head Cover 2 Remove Head Cover and put it aside 3 Remove Lamp carefully from its holder and disconnect lamp socket 4 Mount new lamp and close case using step 1 3 in reverse order Attention Make sure that the lamp and the ...

Page 13: ...r cleaning the case 6 1 Optical System Clean the M Ma ax x optical system with a moistened cloth and a little cleaner Remove the Lens holder to clean the lens ATTENTION Let everything dry carefully before connect AC Power 6 2 Cleaning the Fans It is necessary to clean the fan openings air channels and fan gratings on a regular basis depending on the local environment ATTENTION If using the Max on ...

Page 14: ...rview Supply data 230 120 Volt 5x20 3 15AT 6 3AT Lamp 24V 250W ELC GX 5 3 DMX 512 Standard Weight 13 5 kg Dimensions 240 x 335 x 430 mm 21 gobos 20 dichroitic colors High speed Shutter Stand alone Music controlled Base 1U 12 min 120U min Head 1U 4min 60U min ...

Page 15: ...GLP German Light Production V2 1 15 ...