2.3 Securing the Fixture
Regardless of the mounting method of the
I
I
M
M
P
P
R
R
E
E
S
S
S
S
I
I
O
O
N
N
X
X
4
4
S
S
you'll have to use
a stipulated safety wire. Attach the safety wire through one of the two holes
provided on the base of the fixture and connect it to the primary support
structure. Pay attention to a safe and proper fastening. The safety cable must
comply with BGI 810-3 (EN 60598-2-17 Section 17.6.6) and be capable of
bearing a static suspended load that is ten times the weight of the fixture and all
installed accessories.
2.4 Connections
2.4.1 Power Supply
~100-240 Volt AC, 50-60 Hz, powerCON AC connector
Connected load 200 VA (W)
T2A (2x micro-fuse 5x20mm)
Please also see the printing on the case!
Disconnect from the mains supply for changing the fuse and use
only the above described micro-fuse type.
2.4.2 NEUTRIK
powerCON
The
I
I
M
M
P
P
R
R
E
E
S
S
S
S
I
I
O
O
N
N
X
X
4
4
S
S
is fitted with NEUTRIK
powerCON locking 3
conductor AC connectors. Up to max. 30
i
i
m
m
p
p
r
r
e
e
s
s
s
s
i
i
o
o
n
n
X
X
4
4
S
S
can be linked
via the power outlets staying within the power limits of the 20A of the
connectors.
Note: Regional regulations and
limits might be lower and differ
from that.
Please also note that there are two different generations of NEUTRIK
powerCON connectors (Type NAC3FCA). Due to different mechanical
dimensions, only the newer version of these two can be used for
i
i
m
m
p
p
r
r
e
e
s
s
s
s
i
i
o
o
n
n
X
X
4
4
S
S
fixtures.
You can identify the correct version by the imprint on the side and the
NEUTRIK
Logo on the lock latch.
Picture: Courtesy of NEUTRIK
AG
blue
grey