Locking and unlocking the Control Panel 

Please lock and unlock the control panel by pressing the menu keys MODE & ENTER & UP at the 

same time.  

 

Additional Display Indications  

As a default you'll find the following additional information in the first row of the LCD display:  

Vxx/xx/xx/xx/x (e.g. V1.09/10/16/NN/NS) 
 

 

 NS  ( DMX Mode = Normal / Dimmer Mode = Soft) 

 

 

 NN ( Pan Mode =Normal; Tilt Mode = Normal) 

 

 

 16 = Pan/ Tilt Driver Version 

 

 

 10 LED driver version 

 

 

 1.09 Main CPU version 

 

 

5

5

 

  Maintaining and Cleaning the 

I

I

M

M

P

P

R

R

E

E

S

S

S

S

I

I

O

O

N

N

 

 

X

X

4

4

S

S

 

 

 

 

The 

I

I

M

M

P

P

R

R

E

E

S

S

S

S

I

I

O

O

N

N

 

 

X

X

4

4

S

S is a fixture of very low maintenance. It is only necessary to 

clean the air inlets and outlets as well as the optical LED lenses from time to time. 

For safe operation it is absolutely essential that the fixture is kept clean and that dust, 

dirt and smoke-fluid residues must not build up on, or within the fixture. Otherwise the 

fixture's light-output will be significantly reduced or damages can occur. Regular 

cleaning will not only ensure the maximum light-output, but will also allow the fixture 

to operate reliably throughout its life.  

A soft lint-free cloth moistened with any good glass cleaning fluid is recom-

mended, under no circumstances should alcohol or solvents be used! 

5.1 Safety 

regulations 

• 

Pull out the mains power plug! 

• 

Wait min. 15 minutes after disconnecting power to allow the fixture to cool 

down. 

5.2  Maintenance and Interval (rule-of-thumb) 

The contamination of the fixture depends on the environment details. Hence no 

general guidelines can be given. The intervals given below are only suggestions 

from our experience.  

Position 

Interval 

In this way 

LED reflector and optical system 

weekly 

soft brush /lint-free cloth 

Fan and air channel 

monthly 

vacuum cleaner, airbrush, etc. 

Summary of Contents for impression X4S

Page 1: ...Instruction Manual from software version V1 09 Instruction version 1 1 e mail service glp de Internet http www glp de ...

Page 2: ...GLP German Light Products GmbH Instruction version 1 1 from software version V1 09 2 Notes ...

Page 3: ...oor Upright 8 2 2 2 Mounting in hanging position 8 2 2 3 Mounting in sideways Position 8 2 3 Securing the Fixture 9 2 4 Connections 9 2 4 1 Power Supply 9 2 4 2 DMX 9 3 The Menu Field 10 4 DMX Channel Selection DMX Protocol 12 5 Maintaining and Cleaning the I IM MP PR RE ES SS SI IO ON N X X4 4S S 16 5 1 Safety regulations 16 5 2 Maintenance and Interval rule of thumb 16 5 3 Changing the Fuse 17 6...

Page 4: ... Device 1 Moving head actively and passively cooled 2 Arm of device 3 LCD Display Menu data entry 4 Base with various connectors air in outlets and mounting system 5 Fuse holder 1 2 3 4 5 ba se sid e 1 6 7 base s id e 2 8 9 6 Power On Off 7 DMX Output 5 pin 8 DMX Input 5 pin 9 Mains supply fixed cable ...

Page 5: ... necessary to wait at least 15 minutes after disconnecting the mains power before handling the fixture Pay attention to possible hot parts of the fixture Danger of BURNING 6 Never look directly into the beam of light or into one of the LEDs Never use optical apertures to observe the beam of light LED Class 2M You ll risk serious injury of your eyes and in particular of your retina Attention LED Cl...

Page 6: ...id these possible problems please adhere to the following requirements Do not expose the front of a fixture to direct sunlight or any other strong light sources For outdoor applications during daylight make sure that the front face of any fixture is either shielded or points away from the sun even when fixtures are not in use Do not modify the front glass or lenses of any fixture These requirement...

Page 7: ...C1 former VBG 70 DIN VDE 0711 217 and BGI 810 3 The installation shall be done by qualified staff only For the various mounting positions of the I IM MP PR RE ES SS SI IO ON N X X4 4S S standing on the floor sideways or hanging different connectors are available Through this a safe and firm installation is assured You ll find dedicated M10 threads on the bottom side of the fixture which should be ...

Page 8: ...clamp This can be mounted directly to the bottom side of the fixture It should be attached centrically with a M10 mm thread bolt max length 11mm Attention Never use a longer bolt as this may damage the interior of the fixture 2 2 3 Mounting in sideways Position To operate the I IM MP PR RE ES SS SI IO ON N X X4 4S S in a sideways position please use two half couplers clamps attached to the bottom ...

Page 9: ... structure Pay attention to a safe and proper fastening The safety cable must comply with BGI 810 3 EN 60598 2 17 Section 17 6 6 and be capable of bearing a static suspended load that is ten times the weight of the fixture and all installed accessories 2 4 Connections 2 4 1 Power Supply 100 240 Volt AC 50 60 Hz earth contact type plug Connected load 130 VA W T5A micro fuse 5x20mm Please see printi...

Page 10: ...an Manual control for Pan X movement Pattern Byte 1 Manual control for Pattern Byte 1 LED 1 7 Pattern Manual control for Pattern channel bank Zoom Manual control for Zoom Speed Movements Manual control for Pan Tilt movements Pan Tilt Movements Manual control for Pan Tilt movements Special White Temperature Manual control for Color temperature Dimmer Manual control for Dimmer Shutter Manual control...

Page 11: ...for Pan Tilt movements Special Instantaneous value for Special White Temperature Adjustment of the color temperature for WHITE Dimmer Instantaneous value for Dimmer Shutter Instantaneous value for Shutter White Instantaneous value for White Blue Instantaneous value for Blue Green Instantaneous value for Green Red Instantaneous value for Red Color Wheel Instantaneous value for Color Mixing unit Set...

Page 12: ... 80 50 Rainbow Effect 3 slow fast 129 223 81 DF 51 88 Random colors slow fast 224 255 E0 FF 89 100 6 Red Color mixing system Red 0 100 0 255 00 FF 0 100 7 Green Color mixing system Green 0 100 0 255 00 FF 0 100 8 Blue Color mixing system Blue 0 100 0 255 00 FF 0 100 9 White Color mixing system White 0 100 0 255 00 FF 0 100 10 Shutter Shutter closed 0 15 00 0F 0 5 5 Shutter pulse random slow fast 1...

Page 13: ... 224 255 E0 FF 88 100 15 Speed Pan Tilt movement speed from controller 0 1 00 01 0 0 5 Pan Tilt Pan Tilt slow fast Use this channel also for the speed of the movements channel 14 02 255 02 FF 1 100 16 Zoom Wide narrow spot 0 255 00 FF 0 100 17 Pattern No pattern 0 2 00 02 0 1 Pre defined patterns 03 253 03 FD 2 99 Activates direct access to LED Pattern 254 255 FE FF 100 18 Pattern Byte 1 Direct ac...

Page 14: ... Random Pulse effect slow fast 16 47 10 2F 6 18 5 Up dimming then Shutter closing random patterns slow fast 48 79 30 4F 19 31 5 Shutter open then down dimming random patterns slow fast 80 111 50 6F 32 43 Up dimming then down dimming random patterns slow fast 112 143 70 8F 44 56 Strobe effect pause 5s 1s 144 199 A0 C7 57 77 Strobe effect slow fast 1 Hz 10 Hz 200 239 C8 EF 78 94 Shutter open 240 249...

Page 15: ...rse Dimmer 0 100 0 255 0 FF 0 100 15 Dimmer fine Dimmer Low 0 255 0 FF 0 100 16 Zoom Spot Flood 0 255 00 FF 0 100 17 Special Pattern Block 1 channel 18 0 3 00 03 0 1 Change PWM frequency 100 200 64 C8 40 78 RESET 250 255 FA FF 98 100 18 Pattern No pattern 0 2 00 02 0 1 Pre defined patterns 03 253 03 FD 2 99 Activates direct access to LED Pattern 254 255 FE FF 100 19 Pattern Byte 1 Direct access to...

Page 16: ...n it is absolutely essential that the fixture is kept clean and that dust dirt and smoke fluid residues must not build up on or within the fixture Otherwise the fixture s light output will be significantly reduced or damages can occur Regular cleaning will not only ensure the maximum light output but will also allow the fixture to operate reliably throughout its life A soft lint free cloth moisten...

Page 17: ... Fuse Follow the safety regulations as described above The micro fuse holder 2 is located on the topside of the base In order to attain access you first need to remove one of the two plastic side covers of the fixture arm Open the two screws no 1 shown in the picture below Replace the fuse with one with the exact rating as printed in this manual or the body of the fixture Never use a different one...

Page 18: ...r space Optical System Full RGBW High efficient Collimator cluster Shutter Dimmer 8 16 Bit Strobe Effect with variable speed between 1 10 flashes per second Random Strobe Pulse Effects Continuous Dimmer 0 100 Zoom 7 to 50 degree continuous zoom Optical Patterns Several hundred pre defined beam patterns with direct access and manipulation DMX Control Standard USITT DMX 512 5 pin XLR Pin 3 Pin 2 Gro...

Page 19: ...GLP German Light Products GmbH Instruction version 1 1 from software version V1 09 19 7 Dimensions 3x M10 length max 11mm ...

Page 20: ...ode 14 I Instruction Version 1 Internet 1 L LED Class 2M 5 M Maintenance 16 Menu Field 10 Micro fuse 9 Mode key 10 Mounting 7 Mounting in hanging Position 8 Mounting in sidewise Position 8 Mounting on the Floor 8 N Normal Mode 12 O Optical parts 17 P Pan Movement 18 plano convex lenses 6 Power Supply 9 R RESET 12 S Safety distance 7 Safety information 6 Safety Instructions 5 Secure the Device 9 So...

Page 21: ...GLP German Light Products GmbH Instruction version 1 1 from software version V1 09 21 ...

Reviews: