following information explains the requirements for
power cord set selection.
The cord set must be approved for the country in
which it is used.
The appliance coupler must have a configuration
for mating with a CEE7/EN60320/IEC 320/NEMA/
JIS C 8303 appliance inlet.
A.
For U.S. and Canada:
The cord set must be UL Listed and CSA
Certified.
The minimum specifications for the flexible cord
are No. 18 AWG, (2) Type SPT-2, and (3) 2-
conductor.
B.
For Japan:
All components of the cord set must bear a PSE
mark in accordance with the Japanese DENAN
Law.
The minimum specifications for the flexible cord
are .75mm² conductors, (2) Type VCTR or VCTFK,
and (3) 2-conductor.
The cord set must have minimum rated current
capacity of 7 A.
The attachment plug must be a two-pole,
grounded type with a Japanese Industrial
Standard C8303 (15A, 125 VAC) configuration.
C.
For other countries:
The cord set fittings must bear the certification
mark of the agency responsible for evaluation in
a specific country.
The flexible cord must be of a HAR (harmonized)
type H03VVH2-F.
The cord set must have a current capacity of a
least 2.5 Amperes and voltage rating of 125 or
250 VAC.
Summary of Contents for Q10 Air
Page 1: ...Q10 Air Subnotebook USER S GUIDE...
Page 41: ...USER S MANUAL ENGLISH 37...
Page 42: ...ENGLISH Q10 Air 38 Info Advanced...
Page 43: ...USER S MANUAL ENGLISH 39 Security Power...
Page 44: ...ENGLISH Q10 Air 40 Boot Exit...
Page 46: ...ENGLISH Q10 Air 42 Display Devices...
Page 47: ...USER S MANUAL ENGLISH 43 Display Settings Color Correction...
Page 48: ...ENGLISH Q10 Air 44 Hot Keys...