4.1.2. Replacing filter cartridge. 

 

The filter cartridge should be replaced after 4000-8000 

hours of operation or after 4 years.

 

This is dependent of the load put on the filter.

 

 

Procedure:

1.  Before dismounting the service hatch on the side 

of the filter it is very important that the service tech

-

nician is properly protected using safety gear. 

2.  All power must be disconnected. Make sure that 

the power can not be turned on by accident. 

3.  The compressed air connection should be discon-

nected using the ball valve.

 

If a ball valve is not fitted, shut off the compressor 

and empty the tank manually using release button.

4.  Unscrew all finger screws and remove the service 

hatch.

5.  The filter cartridge is held in place by three latches 

in a flange at the top of the cartridge.

 

6.  Loosen the filter cartridge my simply turning it so 

that the latches release. 

7.  Carefully remove the contaminated filter cartridge 

and place it in a large sealed plastic bag.

 

8.  Carefully place the new filter cartridge and secure 

it by turning it.  

9.  Reattach the service hatch and fasten the screws.

 

(Remember to reconnect power and compressed 

air.)

10.  Control the filter for function and leaks.

11.  Dispose of the contaminated filter cartridge in a 

secure manner as prescribed by local authorities.  

Summary of Contents for Dustbox CFU-1000

Page 1: ...D U S T B O X CFU 1000 Version1 0 05 01 15 I N S T R U C T I O N S M A N U A L www geovent dk...

Page 2: ...released after each use Press the button on the side of the filter to release the valve 1 3 Technical specifications Compressed air Max 3 5 bar clean and dry air Air consumption 3 0 liter min Power s...

Page 3: ...Dustbox CFU 1000 is connected to circular ducts on both dirty and clean side The lower duct connection is always the dirty side Seal the duct connection using tape or rub ber seal 3 To ensure free mix...

Page 4: ...service technician Periodic maintenance All electrical components should be checked yearly Make sure that the air supply for the compressed air system is clean and dry Otherwise the filter cartridges...

Page 5: ...ot fitted shut off the compressor and empty the tank manually using release button 4 Unscrew all finger screws and remove the service hatch 5 The filter cartridge is held in place by three latches in...

Page 6: ...new time is saved the unit will start operating with the new time setting Default values ON 0 2 seconds OFF 30 seconds If the desired OFF time is set then simply don t press any buttons and after a f...

Page 7: ...user fitter must follow this In struction Manual in all respects Under no circumstances may the products be changed in any way without prior written consent from Geovent A S 4 2 Trouble shooting In ca...

Page 8: ...VENT DK hereby declares that The product Geovent Dustbox CFU 1000 has been manufactured in compliance with the directions of the Directive Council of 14 June 1989 in common approximation to the legisl...

Reviews: