GEOTECH PVT DIRECT PUSH PIEZOMETER Manual
2015-11-11
3
Product Information
Fig. 2 – Logging direct push piezometer with memory: Small movements of the sensor membrane
result in changes of electrical parameters that are detected, amplified and passed through an A/D
converter. The data are processed in the microcontroller and saved in the on-board memory.
Modern electronics and power saving technology enables permanent installation of the equipment for
several years without any need for battery change or charging. Logging intervals are programmed from
your computer with interface and two crocodile clip wires. The same setup is used for uploading log files
and for viewing the real-time value of pressure and temperature.
Direct push piezometer without memory
2.3
Connect your computer with crocodile clip interface to the piezometer for real-time reading of temperature
and pressure.
The piezometers can alternatively be connected to a local network with a telematics unit for remote moni-
toring and/or instant alarms upon critical values.
Fig. 3 – Pressure and temperature real-time values are instantly available when connecting the
piezometer to the crocodile clips of the handheld reading kit. Have the similar functionality with
you own standard computer – just install the PVTLog software and connect the USB/crocodile clip
interface (read-out kit for PC).