background image

 

21 

 

The Warranty 

 
For a period of one (1) year from date of first sale, product is warranted to be free from 
defects in materials and workmanship. 

Geotech agrees to repair or replace, at Geotech’s 

option, the portion proving defective, or at our option to refund the purchase price thereof. 
Geotech will have no warranty obligation if the product is subjected to abnormal operating 
conditions, accident, abuse, misuse, unauthorized modification, alteration, repair, or 
replacement of wear parts. User assumes all other risk, if any, including the risk of injury, 
loss, or damage, direct or consequential, arising out of the use, misuse, or inability to use 
this product. User agrees to use, maintain and install product in accordance with 
recommendations and instructions. User is responsible for transportation charges 
connected to the repair or replacement of product under this warranty. 
 

Equipment Return Policy 

 
A Return Material Authorization number (RMA #) is required prior to return of any 
equipment to our facilities, please call our 800 number for appropriate location. An RMA # 
will be issued upon receipt of your request to return equipment, which should include 
reasons for the return. Your return shipment to us must have this RMA # clearly marked 
on the outside of the package. Proof of date of purchase is required for processing of all 
warranty requests. 
 
This policy applies to both equipment sales and repair orders. 
 

FOR A RETURN MATERIAL AUTHORIZATION, PLEASE CALL OUR 

SERVICE DEPARTMENT AT 1-800-833-7958. 

 
Model Number:    

________________ 

 
Serial Number:    

________________ 

 
Date of Purchase: 

________________ 

 
 

Equipment Decontamination 

 
Prior to return, all equipment must be thoroughly cleaned and decontaminated. Please 
make note on RMA form, the use of equipment, contaminants equipment was exposed to, 
and decontamination solutions/methods used. Geotech reserves the right to refuse any 
equipment not properly decontaminated. Geotech may also choose to decontaminate the 
equipment for a fee, which will be applied to the repair order invoice. 

 

 
 

 
 

Summary of Contents for PRC

Page 1: ...Rev 10 27 2020 Part 26650319 Product Recovery Canister Installation and Operation Manual...

Page 2: ......

Page 3: ...and Theory 3 System Components 3 Section 2 System Installation and Operation 4 Section 3 System Maintenance 6 Section 4 System Troubleshooting 7 Section 5 System Specifications 9 Section 6 System Sche...

Page 4: ...ceed until you read and thoroughly understand the WARNING message WARNING CAUTION A raised hand icon indicates CAUTION information that relates to a situation or condition that could lead to equipment...

Page 5: ...System Components A PRC consists of two 2 major components a product skimmer assembly and a collection canister as shown in Figures 1 1 through 1 3 On the 4 model the skimmer assembly is protected by...

Page 6: ...4 Figure 1 1 2 PRC Skimmer Assembly Figure 1 2 4 PRC Skimmer Assembly 1 liter Figure 1 3 4 PRC Skimmer Assembly 3 liter...

Page 7: ...nt To empty the collection canister simply pull the PRC up from the well open the drain valve by applying a downward pulling force on the valve sleeve like a water bottle and transfer the recovered pr...

Page 8: ...bstructions such as kinks Replace the tubing coil as necessary 3 Inspect the collection canister for physical damage such as cracks Replace as necessary 4 To clean the intake assembly screen intake us...

Page 9: ...em The drain valve is not fully closed Solution Empty the collection canister as described in Section 2 System Installation and Operation and then close the drain valve by pushing up on the outer slee...

Page 10: ...scribed in Section 2 System Installation and Operation Problem The canister vent is blocked Solution Make sure that the holes in the suspension fitting are clear of debris The PRC will not operate if...

Page 11: ...OD 4 8cm 1 82 5 L 210cm x 1 88 OD 4 8cm 4 1 37 L 94cm x 3 5 OD 9cm 3 53 0 L 135cm x 3 5 OD 9cm 4 60 0 L 152cm x 3 5 OD 9cm Weight Size Volume L Empty Weight Full Weight 2 0 125 2 9lbs 1 3kg 3 1lbs 1 4...

Page 12: ...ume L Capacity gallons 2 0 125 0 035 0 25 0 07 0 5 0 13 1 0 26 4 1 0 26 3 0 8 4 1 06 Minimum Water Required Size Volume L Depth 2 0 125 23 5 60cm 0 25 29 0 74cm 0 5 39 5 100cm 1 62 0 157cm 4 1 18 5 47...

Page 13: ...11 Section 6 System Schematic Figure 6 1 PRC Skimmer deployed in well...

Page 14: ...12 Section 7 Replacement Parts List Figure 7 1 Standard 2 PRC Skimmer Assembly...

Page 15: ...50304 11 CAP PVC TOP PRC2 26650315 12 BODY PVC CANISTER 0 125L PRC 26650321 BODY PVC CANISTER 0 25L PRC 26650307 BODY PVC CANISTER 0 5L PRC 26650311 BODY PVC CANISTER 1LITER PRC 26650313 13 ASSY WEIGH...

Page 16: ...14 Figure 7 2 Standard 4 PRC Skimmer Assembly 1 Liter...

Page 17: ...UPLER PVC PRC4 16650316 8 SCREEN PVC PRC4 16650317 9 HOSEBARB BRS 170 X1 8MPT 90D 17500148 10 CANISTER 1L PRC4 W BTM PLATE 56650311 11 CLAMP SS STEPLESS EAR 7MM 16600005 12 CLAMP SS6 CABLE LOW PRFL 16...

Page 18: ...16 Figure 7 3 Standard 4 PRC Skimmer Assembly 3 4 Liter...

Page 19: ...CANISTER PVC 4L PRC4 16650320 10 WEIGHT SS4 3L 4L PRC4 16650319 11 CLAMP SS STEPLESS EAR 7MM 16600005 12 HOSEBARB BRS 170 X1 8MPT 90D 3 LITER 17500148 HOSEBARB BRS 1 8 X1 8 NPT 4 LITER 16600065 13 O...

Page 20: ...0125 specs to system specifications added revision history StellaR 6 27 2018 1670 Corrected table title in Section 5 System specifications Corrected weight for 125 volume StellaR 6 29 2018 2093 Added...

Page 21: ...19 NOTES...

Page 22: ...20 NOTES...

Page 23: ...al Authorization number RMA is required prior to return of any equipment to our facilities please call our 800 number for appropriate location An RMA will be issued upon receipt of your request to ret...

Page 24: ...Geotech Environmental Equipment Inc 2650 East 40th Avenue Denver Colorado 80205 303 320 4764 800 833 7958 FAX 303 322 7242 email sales geotechenv com website www geotechenv com...