Geotech Keck 1500 Installation And Operation Manual Download Page 18

 

16 

The Warranty 

For a period of one (1) year from date of first sale, product is warranted to 
be free from defects in materials and workmanship.  Geotech agrees to 
repair or replace, at Geotech’s option, the portion proving defective, or at 
our option to refund the purchase price thereof.  Geotech will have no 
warranty obligation if the product is subjected to abnormal operating 
conditions, accident, abuse, misuse, unauthorized modification, alteration, 
repair, or replacement of wear parts.  User assumes all other risk, if any, 
including the risk of injury, loss, or damage, direct or consequential, 
arising out of the use, misuse, or inability to use this product.  User 
agrees to use, maintain and install product in accordance with 
recommendations and instructions.  User is responsible for transportation 
charges connected to the repair or replacement of product under this 
warranty. 

Equipment Return Policy 

A Return Material Authorization number (RMA #) is required prior to 
return of any equipment to our facilities, please call 800 number for 
appropriate location.  An RMA # will be issued upon receipt of your 
request to return equipment, which should include reasons for the return.  
Your return shipment to us must have this RMA # clearly marked on the 
outside of the package.  Proof of date of purchase is required for 
processing of all warranty requests. 
 
This policy applies to both equipment sales and repair orders. 
 
FOR A RETURN MATERIAL AUTHORIZATION, PLEASE CALL OUR 
SERVICE DEPARTMENT AT 1-800-833-7958 OR 1-800-275-5325. 
 
Model Number:  ________________ 
 
Serial Number:   ________________ 
 
Date: ________________ 

Equipment Decontamination 

Prior to return, all equipment must be thoroughly cleaned and 
decontaminated.  Please make note on RMA form, the use of equipment, 
contaminants equipment was exposed to, and decontamination 
solutions/methods used. 
Geotech reserves the right to refuse any equipment not properly 
decontaminated.  Geotech may also choose to decontaminate equipment 
for a fee, which will be applied to the repair order invoice.

Summary of Contents for Keck 1500

Page 1: ...Rev 2 09 09 09 Part 12050339 Keck 1500 2000 ET Tuff Tape Water Level Meters with optional electric rewind Installation and operation Manual...

Page 2: ......

Page 3: ...NSTALLATION 6 MANUAL REEL 6 ELECTRIC REEL 6 CHAPTER 3 SYSTEM OPERATION 7 CHAPTER 4 SYSTEM MAINTENANCE 8 CHAPTER 5 SYSTEM TROUBLESHOOTING 9 CHAPTER 6 SYSTEM SPECIFICATIONS 11 CHAPTER 7 SYSTEM SCHEMATIC...

Page 4: ...ceed until you read and thoroughly understand the WARNING message WARNING CAUTION A raised hand icon indicates CAUTION information that relates to a situation or condition that could lead to equipment...

Page 5: ...O D stainless steel weighted probe attached to a polyethylene tape marked to 1 100th of a foot The meter relies on fluid conductivity to determine the presence of water An audible signal and visible L...

Page 6: ...4 System Components Figure 1 Manual Reel Front View Figure 2 Manual Reel Side View Visible Signal Power On Sensitivity switch Reel Handle Engineers tape Frame Pin Lock Brake 5 8 Probe...

Page 7: ...5 Figure 3 Electric Reel Front View Figure 4 Electric Reel Side View Visible Signal Power On Sensitivity Switch Probe Battery Clips Speed Control Up Down Push Buttons Frame Probe holder...

Page 8: ...ositive battery terminal and black clip to the negative battery terminal 3 Turn the speed control dial fully counter clockwise Press desired button up down Slowly rotate the speed control until reel i...

Page 9: ...still in contact with the water adjust the probe sensitivity dial clockwise until the light and buzzer barely activate In this setting the probe will detect water levels but will not be affected by fa...

Page 10: ...an be cleaned with any detergent such as trisodium phosphate TSP Alconox or Liquinox If other detergents are used take care to select detergents that are compatible with Teflon polyethylene and stainl...

Page 11: ...NO INDICATION OF WATER Solutions 1 The conductive contact is dirty Clean the contact see page 8 2 There is an open connection in the tape Replace tape and or probe 3 The circuit is malfunctioning Cons...

Page 12: ...ctive contact is dirty causing bridging Clean the contact see page 8 2 There is a short in the tape and or probe Replace tape and or probe 3 The circuit is malfunctioning Consult the manufacturer For...

Page 13: ...1500 450 m 50 4 lbs man 1500 450 m 60 5 lbs elec 2000 600 m 70 4 lbs man 2000 600m 80 5 lbs elec Tape accuracy 100th of a foot 100 Reel Frame Material Steel and Aluminum Size 18 25 H x 14 W x 15 L man...

Page 14: ...12 Chapter 7 System Schematic Manual Reel Front and Side view Electric Reel Front and side view 14 10 16 5 15 20 10 14 16 5...

Page 15: ...cription 52050144 Reel assy 1500 2000 manual 52050145 Reel assy 1500 2000 electric 52050124 Tape assy poly 1500 52050125 Tape assy poly 2000 52050248 Tape assy poly 450 m 52050249 Tape assy poly 600 m...

Page 16: ...14 Notes...

Page 17: ...15 Notes...

Page 18: ...ial Authorization number RMA is required prior to return of any equipment to our facilities please call 800 number for appropriate location An RMA will be issued upon receipt of your request to return...

Page 19: ......

Page 20: ...ver Colorado 80205 303 320 4764 800 833 7958 FAX 303 322 7242 email sales geotechenv com website www geotechenv com In Michigan Call Geotech Environmental Equipment Inc 1099 West River Avenue Williams...

Reviews: