5
Section 2: System Installation
Attach the Air (A), Vent (V), and Discharge (D) hoses/tubing to their appropriate labeled
fittings (see Figure 2-1). Ensure all hoses are installed securely and completely. Top filling
AR4 pump models have a screened inlet in the Fill (F) port; bottom fill only pumps will have
this port plugged.
Attach the pump suspension cable to the safety cable harness and lower pump into well.
Suspension cable should be centered with the pump head and not wrapped around any of
the fittings or tubing.
Lower the pump into the well so that the appropriate intake(s) becomes submerged below
static groundwater conditions.
Figure 2-1:
Pump Head
Summary of Contents for 86600149
Page 1: ...Rev 3 31 2020 Part 16600115 AR4 4 Auto Reclaimer Installation and Operation Manual...
Page 2: ......
Page 13: ...12 Figure 2 8 Trunkline Sizing 15PSI Pressure Drop...
Page 22: ...21 Figure 4 12 AR4 EXT Bottom Top Inlet 10 3 m Submergence 3 4 19 mm ID Hose in GPM...
Page 24: ...23 Replacement Parts Diagram OPTIONAL QUICK CONNECTS QCON...
Page 25: ...24...
Page 40: ...39 Air Supply Pressure Drops Metric continued Figure A 16 Air Pressure Drop at 7 Kg cm...