MAINTENANCE

TROUBLESHOOTING

5

• Unplug unit and inspect the pump intake grill after 

every hour of cleaning (Fig D). Clean more often if 

removing excessively heavy deposits of grease and 
grit. 

Important Note:

Failure to clean pump intake will result in diminished fl 

uid fl ow, cleaning effectiveness and eventual pump 

motor failure.

• If it becomes apparent that the pump intake grill 

requires cleaning more often, it is likely that the clean-

ing solution needs to be replaced and an accumulation 

of sediment from the Tub bottom needs to be removed.

- Drain and pour drain cleaning solution into suitable 

containers and dispose of properly.

• If Fluid stops fl owing or fl ows sporadically, the Pump may not be fully submersed. The Pump

must be fully under the fl uid surface level to work properly (Fig C).

• If pump intake cleaning does not restore pump performance, an accumulation of dirt and grit

may be present in the Flexible Metal “Gooseneck” Fluid Outlet Tube.

- Unplug unit and remove Flexible Metal “Gooseneck” Fluid Outlet Tube and check for

obstructions lodged in tube and remove.