15
APPENDIX A. SPECIFICATIONS
A.1 Model 4410 Vibrating Wire Strandmeter
Range:¹
3 mm
0.125 inches
Resolution:²
0.025% FSR
Accuracy:
3
±0.1% F.S.
Linearity:
0.25% FSR
Thermal Zero Shift:
< 0.05% FSR/°C
Stability:
< 0.2%/yr (under static conditions)
Overrange:
115%
Temperature
Range:
-20 to +80 °C
-4 to 176 °F
Frequency Range:
1200 - 2800 Hz
Coil Resistance:
150
Ω
,
±
10
Ω
Cable Type:
4
Two twisted pair (four conductor) 22 AWG
Foil shield, PVC jacket, nominal OD=6.3 mm (0.250")
Length x Width
203 x 45 mm (clamp width)
Weight:
(with gage clamps)
0.5 kg.
1.1 lb.
Table 4 - Model 4410 Strandmeter Specifications
Notes:
¹ Other ranges available, consult factory.
² Minimum, greater resolution possible depending on readout.
3
Accuracy established under lab conditions.
4
Polyurethane jacket cable available.
A.2 Thermistor (see Appendix B also)
Range: -80 to +150 °C
Accuracy: ±0.5 °C