![Geokon 4200ER Instruction Manual Download Page 20](http://html.mh-extra.com/html/geokon/4200er/4200er_instruction-manual_2214541020.webp)
14
APPENDIX A - SPECIFICATIONS
A.1 4200ER Strain Gage
Model: 4200ER
Range (nominal):
10,000
Resolution:
5.0
¹
Calibration
Accuracy
0.5%FSR
Sytem Accuracy:
2.0% FSR²
Stability: 0.1%FS/yr
Linearity: +/-3.0%
FSR
Thermal
Coefficient:
variable
Frequency Range
Hz:
400-1200
Dimensions (gage):
(Length
Diameter)
6.00 x 0.750"
153
19 mm
Dimensions (coil):
0.875
0.875"
22
22 mm
Coil Resistance:
50
Temperature
Range:
-20 to +80
C
Table A-1 Strain Gage Specifications
Notes:
¹ Depends on the readout; figures in Table A-1 pertain to the GK-403 or GK-404 Readout.
² System Accuracy takes into account hysteresis, non-linearity, misalignment, batch factor
variations, and other aspects of the actual measurement program.
A.2 Thermistor (see Appendix C also)
Range: -80 to +150° C
Accuracy: ±0.5° C