Kit Includes 

 

The UPM replacement kit includes the following components required for the replacement from 
all previous board versions. 

Included in this kit 

Description Qty 

Screws 1"  

UPM I Replacement Instructions 

UPM I IOM 

Nylon Tubular Sleeves 

Unit Protection Module, UPM-I 

Freeze sensor jumper Assembly 

Ground harness Assembly 

Needs to be updated

 

Installation Procedure

 

 

Controller  shall  be  installed  inside  the  unit 
electrical  box;  mounting  holes  are  available 
on  the  location  of  the  previous  board.  The 
plastic stand-offs from the UPM board match 
the pilot holes on the electrical box.   

Remove Old Board 

1.

 

Locate  existing  UPM  in  unit  electrical 
box. 

2.

 

Verify old part number on the old board 
as one of the four listed on page 3. 

3.

 

Take  a  picture  or  LABEL  all  wires 
currently  present  and  according  to  the 
terminal  designations  on  the  UPM 
board. 

4.

 

Disconnect  all  the  previously  labeled 
wires. 

5.

 

Remove existing circuit board. 

Mounting Holes 

If existing UPM has plastic stand-offs, pinch 
the  tab  on  the  stand-off  from  the  top  side 
and  push  downward  to  release  it  from  the 
circuit board as shown in 

Figure 2

. The snap 

the new board onto the stand-offs. 

If  existing  UPM  does  NOT  have  plastic 
stand-offs, choose one of the following: 

A.

 

If drilling is possible bigger pilot holes 
will need to be made.  

1.

 

Use  a  unit  bit  or  a  3/16”  (0.187”) 
drill bit to enlarge the existing pilot 
hole of the electrical box.  

Summary of Contents for 8733 800-259

Page 1: ...1 8733 800 259 KIT Replacement Kit 641 176 641 187 641 225 641 244 IOM...

Page 2: ...THE UPM CONTROLLER 3 SPECIFICATIONS 4 KIT INCLUDES 5 INSTALLATION PROCEDURE 5 Remove Old Board 5 Mounting holes 5 Wiring Installation 6 Sensor Installation 8 FINAL PROCEDURES 10 Table of Contents 2...

Page 3: ...ensate overflow protection if sensors are installed The controller is programmed and it is backwards compatible for most functions of its earlier versions This controller can be used as replacement fo...

Page 4: ...purposes dry contact Normally Open NO Inputs Four 4 inputs Dedicated inputs for High Pressure Switch HPC Low Pressure Switch LPC Freeze Sensor FREEZE 10 K 77F Thermistor Condensate Overflow Sensor CON...

Page 5: ...Remove Old Board 1 Locate existing UPM in unit electrical box 2 Verify old part number on the old board as one of the four listed on page 3 3 Take a picture or LABEL all wires currently present and a...

Page 6: ...circuit board as shown in Figure 2 2 Secure controller to unit by using four 1 long 6 screws along with the tubular sleeves Figure 2 Plastic Stand Off Wiring Installation Reconnect the wires using th...

Page 7: ...an existing screw that secures an existing component IMPORTANT Ground Do not forget to ground the board If a connection is not available ground the terminal by Avoid sharp edges on unit cabinet durin...

Page 8: ...5 Figure 5 Freeze Sensor s New Location Once the sensor has been relocated use wire ties and cork tape to secure and insulate sensor as shown below in Figure 6 Figure 7 and Figure 8 If this is a new...

Page 9: ...Figure 6 Sensor with Wire Ties Figure 7 Wire Tied Sensor with Cork Tape Figure 8 Final Sensor Installation with Insulating Tape 9...

Page 10: ...and their corresponding faults are shown 1 High Pressure Switch 2 Low Pressure Switch 3 Freeze Protection 4 Condensate Sensor 5 Brownout Protection A COND error will result in a hard lockout requiring...

Page 11: ...11...

Page 12: ...12 Figure 9 UPM Typical Wiring Components...

Page 13: ...13 Figure 10 UPM Operation Flow Chart...

Page 14: ...14 6720220404 REV 8 12...

Reviews: