RGT-03 GSM Thermostat 

 

 

 

6                                              ML_RGT03_V5_english.doc 

 

Target temperature setting: 

1.

 

mTRef:  In  AUTO  and  HOLIDAY  modes  the  temperature  value  can  be  set  between  the 
lower and upper temperature limits. Valid until the next switching time. 

2.

 

TRef:  In  MAN  mode,  the  temperature  value  can  be  set  between  the  lower  and  upper 
temperature limits. (The GSM remote control affects this parameter too.) 

 

GSM remote control 

The control unit has a built in GSM module that makes remote programming possible. Via an SMS 
you  can  change  the  target  temperature  or  you  can  inquire  the  measured  temperature,  the  target 
temperature, the operating mode and the state of the relay. The inquiry also can be done by making 
a phone call and terminating it after two ring tones. The number of the phone must be stored in the 
RGT-03.  The  clock  of  the  control  unit  is  reset  each  time  at  power  back  up.  If  it  is  necessary,  an 
SMS  command  can  synchronize  the  clock,  so  no  needs  manual  adjustments.  An  ALARM  phone 
number  can  be  set.  The  control  unit  will  send  a  warning  message  to  this  number  if  the  measured 
temperature is 

under the lower

 or 

above the upper

 temperature limit by 2°C. 

 
In case a prepaid SIM card is used with the control unit, you can check the balance and the time of 
expire  –  if  any. 

Always  check  carefully  the  terms  of  use  of  your  SIM  card  at  your  mobile 

supplier to ensure continuous connection!

 

  

SMS commands (non case-sensitive) 

There is a PIN number protection against unauthorised access. The PIN number can be 
changed at any time. The factory set value is: 1234 

 

change PIN number: 

[PIN]P[new PIN]                                                                eg.: 1234p5678 

 

change TRef: 

[PIN]T[TRef  in °C, between 5 and 40]                             eg.: 1234t8 

 

store phone number (up to 100 numbers can be stored): 

[PIN]G[phone number in international format] 

 

eg.: 1234g+36201234567 

 

delete phone number: 

[PIN]D[phone number in international format] 

 

eg.: 1234d+36201234567 

 

SMS inquiry 

[PIN]?                                                                                  eg.: 1234? 
 

Optional phone inquiry:

 Call the RGT-03 from a stored phone number; 

terminate

 the call 

after two ring tones. You will receive the answer in SMS.   

 

store ALARM phone number: 

[PIN]N[phone number in international format] 

           eg.: 1234n+36201234567 

 

delete ALARM phone number: 

[PIN]N 

 

 

 

 

                       eg.: 1234n 

 

store OWN (SIM) phone number: 

[PIN]S[phone number in international format] 

           eg.: 1234s+36201234567 

Summary of Contents for RGT-03

Page 1: ...C Programming 7 days 4 set point day Relay switch Single Pole Double Throw voltage 24V 230VAC load 6A ohmic 3A inductive Relay life 100 000 switches Power input 10 13VDC max 110 mA Operating temperat...

Page 2: ...it can be exposed to direct sunlight Mounting The opening for the cables and the mounting holes are located on the bottom of RGT 03 It is advisable to mount the unit above a wall mount box by two scre...

Page 3: ...o the actual application Jumper JP3 and button S1 S2 and S3 will be used 1 Turn power on and wait for displaying the time date 2 Make JP3 shorted by the supplied connector 3 Scroll the menu up or down...

Page 4: ...switch to 21 C lower temp limit upper temp limit P62 Time Saturday 2 switch time 12 00 00 00 23 59 P62 Ref Saturday 2 temperature to switch to 21 C lower temp limit upper temp limit P63 Time Saturday...

Page 5: ...on off by pressing the OK button Please note Do not leave the illumination turned on permanently because the produced heat can lead to false temperature measurement In operation two parameters can be...

Page 6: ...a warning message to this number if the measured temperature is under the lower or above the upper temperature limit by 2 C In case a prepaid SIM card is used with the control unit you can check the b...

Page 7: ...minute for the unit to restart before check The RGT 03 is able to function as a simple thermostat even with no SIM card installed If so the SIM ERROR message will be displayed for 10 seconds after th...

Page 8: ...as a P1 Tcorr value with opposite sign The procedure is detailed under Initial setup Return the control unit to normal operation 25 C should be displayed If correct place the jumper of the heat sensor...

Reviews: