The  RGT-03  is  an  automatic  SMS  programmable 

control  device  made  for  the  temperature  control  of 

apartments,  weekend  houses  or  even  whole 

buildings. 

The 

selectable 

pre-programmed 

algorithms  make  it  ideal  for  the  operation  of  gas, 

oil, electric heating systems (including pumps) and 

air-conditioners. The built in GSM unit provides the 

remote  access  and  guarantees  the  exact  timing. 

Distant  programming  and  the  inquiry  of  data  is 

easily  done  by  simple  SMS  messages,  while  the 

controller  also  can  be  set  on  the  spot  with  three 

buttons and an LCD display.

 

 

Technical data 

Controlling accuracy 

±0,3°C 

Temperature range 

5 … 40°C, in 1°C steps 

Controlling method 

PI (proportional integrating) 

Temperature display 

-3 … 50°C, in 0,1°C steps 

Sensor 

NTC thermistor 10K @ 25°C 

Programming 

7 days, 4 set point/day 

Relay switch  

Single Pole Double Throw 
voltage: 24V-230VAC             
load: 6A ohmic, 3A inductive 

Relay life 

100 000 switches 

Power input 

10 … 13VDC, max. 110 mA 

Operating temperature  -20 … 55°C operation                               

-40 … 85°C transport or storage 

Dimensions 

120x70x25 mm (W, H, D) 

 

Features 

 

Instant and remote programming 

 

Inquiry via SMS or phone call 

 

MANUAL mode: Operates as a thermostat 
with fixed set point through the day. 

 

AUTO mode: Follows a user-defined 
program with 4 target temperatures and 
switching times/day for each day of a week. 

 

HOLIDAY mode: Follows Sunday 
program on the current day and the day 
after. 

 

Temperature override 

 

All data is kept in case of a power loss 

 

Control program for seven different types 
of heating/cooling systems 

 

Optional distantly mounted heat sensor 

 

ALARM SMS in case of  over or under 
heating/cooling 

 

Can be customised at initial setup: 

o

 

Heating/cooling system 

o

 

Temperature shift 

o

 

Safety temperature limit 

o

 

Forced pump operation 

o

 

Weekly program 

o

 

Language of SMS messages 

Summary of Contents for RGT-03

Page 1: ...C Programming 7 days 4 set point day Relay switch Single Pole Double Throw voltage 24V 230VAC load 6A ohmic 3A inductive Relay life 100 000 switches Power input 10 13VDC max 110 mA Operating temperat...

Page 2: ...it can be exposed to direct sunlight Mounting The opening for the cables and the mounting holes are located on the bottom of RGT 03 It is advisable to mount the unit above a wall mount box by two scre...

Page 3: ...o the actual application Jumper JP3 and button S1 S2 and S3 will be used 1 Turn power on and wait for displaying the time date 2 Make JP3 shorted by the supplied connector 3 Scroll the menu up or down...

Page 4: ...switch to 21 C lower temp limit upper temp limit P62 Time Saturday 2 switch time 12 00 00 00 23 59 P62 Ref Saturday 2 temperature to switch to 21 C lower temp limit upper temp limit P63 Time Saturday...

Page 5: ...on off by pressing the OK button Please note Do not leave the illumination turned on permanently because the produced heat can lead to false temperature measurement In operation two parameters can be...

Page 6: ...a warning message to this number if the measured temperature is under the lower or above the upper temperature limit by 2 C In case a prepaid SIM card is used with the control unit you can check the b...

Page 7: ...minute for the unit to restart before check The RGT 03 is able to function as a simple thermostat even with no SIM card installed If so the SIM ERROR message will be displayed for 10 seconds after th...

Page 8: ...as a P1 Tcorr value with opposite sign The procedure is detailed under Initial setup Return the control unit to normal operation 25 C should be displayed If correct place the jumper of the heat sensor...