GEO-Laser KL-90L Operating Instructions Download Page 2

9 - 13

10 - 13

11 - 13

12 - 13

13 - 13

17. Dimensional Sketch

cold

warmth

20. Effects of the Refraction

The laser beam is deflected to cold air.
It is deformed and moved by atmospheric turbulences.

laser beam

   

laser beam after temperature influence

laser beam

   

laser beam after temperature influence

cold

warmth

warmth

cold

Height transfer

Axis transfer by bearing over the plumb line

Axis transfer with the alignment line

14. Transfer Possibilities

Alignment line

2nd plumb

Aim point

Datum

1st plumb

Aim point

plumb line

2.

3.

1.

Set up laser over the axis.

2.

Look over the plumb line and align it to the alignment rod. 

3.

Look over the plumb line to the laser beam and align the laser in the 
direction.

Measuring rod

Height point

Level device

6

5

A

B

Rod reading A

- Rod reading B
+ 65 mm
+ 1/2 
-----------------------
= Pipe invert 

Ø

16. 

KL-90L  laser  class: . . . . . . . . . . . . . . . . . . . . . . . . . . 2,  <  1  mW
KL-91L  laser  class: . . . . . . . . . . . . . . . . . . . . . . . . . 3R,  <  5  mW
Laser:  . . . . . . . . . . . . . . . . . . . . . . . Diode, visible green, 635 nm
Beam  diameter:    . . . . . . . . . . . . . . . . . . . . . . . . . at  laser  13  mm
Range depending on ambient conditions: KL-90L up to 200/ KL-91L up to 500 m

  

Inclination range: . . . . . . . . . . . . . . . . . . . . . . . . - 10 % to + 40 %
Self-levelling range: . . . . . . . . . . . . . . . . . . . . . . . - 5 % to + 40 %
Reading  accuracy: . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.001  %
Permissible deviation: . . . . . . . . . . . . . . . . . . . . . ± 5 mm/100 m %
Direction setting range: . . . . . . . . . . . . . . . . . . . . . . . . ± 5.000 %
Banking  compensation: . . . . . . . . . . . . . . . . . . . . . . . . . . . ±  4°

 

Operating time with 7.4 V lithium ion rechargeable battery: . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . KL-90L/-91L:  up  to  50/34  hours

External power supply: . . . . . . . . . . . . 11 to 14 V DC with cable 0117.02
Undervoltage  cut-out: . . . . . . . . . . . . . . . . . . . . . . . . . . . . yes

 

Watertight: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . to  0.35  bar
Temperature range: . . . . . . . . . . . . . . . . . . . . . . - 10° C to + 50 °C
Dimensions: . . . . . . . . . . . . . . . . . . . . . Ø 130 mm, length 265 mm
Weight:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3  kg

 

 

Range IR remote control:  . . . . . . . . . . . . . . . . . . to 150 m from front

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . to  18  m  from  back

Guarantee:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24  months
CE: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . certified

Technical Specifications

No.  Order no.

Type

Descripton

  

   01  0001.105

KL-90L Pipe laser

   02  0077.36

Transport case

   03  0016.07

KL-04

Target frame

   03  0016.08.002

Plexi target DN 150 - 300

   04  0037.18

NE-80 Power supply/Battery charger

   05  0077.36.002

Double headed wrench 10/13

   06  0019.07

Leg set DN 200 (2 x sliding leg/ 2 x fixing leg)

   07  0019.08

Leg set DN 250 (2 x sliding leg/ 2 x fixing leg)

   08  0019.09

Leg set DN 300 (2 x sliding leg/ 2 x fixing leg)  

    

  

 

1

 

-

 

8  0001.180.1

KL-90L with standard delivery package

 1

 

-

 

8  0001.185.1

KL-91L with standard delivery package

19. Optional Accessories

No.  Order no.

Type

Descripton

  

08

 0016.08.003

Plexi target DN 400 - 500

09

 0026.05

IF-80

IR remote control

10

 0019.10

Leg set DN 400 (2 x sliding leg/ 2 x fixing leg)

11

 0019.11

Leg set DN 500 (2 x sliding leg/ 2 x fixing leg)

12

 0019.90

Leg adapter for mounting with 3 legs

   

     

8

 

-12  0125.02.1

KP-IR-GN Comfort version for pipe laser

1

2

3

4

5

6

7

8

9

10

11

12

8

18. Standard Delivery Package

Table of Contents   

         Page

    

Safety Information . . . . . 1 - 2
Laser safety . . . . . . . . 2 - 3
Repair . . . . . . . . . . . . . 3
EMC . . . . . . . . . . . . . . 3
Guarantee . . . . . . . . . . . 3
Disposal . . . . . . . . . . . . 3

1.

. . . . . . . . . . 5

2.

 5

3. Set-up . . . . . . . . . . . .     5
4.

. . . . .   5  -  6

5. Buttons . . . . . . . . . .   6  -  7

 7-8

 8
 8

  

S1
S2
S3
S4
S4
S5

Description
Pipe Laying made easy . . . .

Laser Description

6. Settings . . . . . . . . . . .
7. Banking Compensation . . . .
8. Infrared Remote Control. . . .

Page

   

11. Battery Charging . . . . . . .  9
12. Trubleshooting . . . . . . . .  9
13. Maintenance . . . . . . . . .  9
14. Transfer Possibilities . . . . . 10
15. Checking of Adjustment . . . 11
16. Technical Specifications . . . 11
17. Dimensional Sketch . . . . . 11
18.  

. 12

19.

. . . . . 12

20.

. . . 13

9. Calculating the Percentage . . 8

10. Power Supply . . . . . . . . . 8

Standard Delivery Package

Optional Accessories
Effects of the Refraction

Although the laser is adjusted precisely by the manufacturer, jolts and strong 
vibrations can lead to maladjustment. The laser should therefore be checked 
before use:

   

1. Select a measuring area of approx. 40 m that is as horizontal as possible and

set up the laser with the counter at 0.000%.

  

2. Set up two control points, one directly in front of the laser and the other in a 

distance of approx. 40 m, and measure the distance on the centre of the laser 
beam 

"a"

 and 

"b"

.

  

3. Set up the laser behind the second measuring point and repeat the measuring 

process in reverse direction, this means measure 

"A"

 and 

"B"

.

  

4. If the adjustment is correct,   A - a = B - b. This means, the laser beam of the first

installation is parallel to the second one.

 

If the adjustment is incorrect, please contact your specialist dealer.

15. Checking of Adjustment

Error-free: A - a = B - b

1st build

A

a

Hz

40 m

B

b

2nd build

Countermeasures:

   

Do not keep tubes in direct insolation. Store tubes in the shadow or cover them 
with a canvas.

   

Align the pipe in the ditch immediately. If the laser beam is deformed by 
temperature influences and/or in movement, define the centre by averaging.

GEO-Laser GmbH

Solinger Str. 8
45481 Muelheim an der Ruhr
Germany

Phone +49 208 99357-0
Fax

+49 208 99357-25

[email protected]
www.geo-laser.de

GEO - partner of the construction industry for 50 years

German Quality Product

CE

Certified

11. Battery Charging

• Carry out charging only with the power and charging unit, type NE-80 or 

a 12 V DC external rechargeable battery via connection cable 0117.02.

• Keep charger dry and only use in rooms.
• For charging take the laser out of the transport case.
• Permissible charging temperature 0°C to + 40°C, as best + 10°C to + 25°C.
• After approx. 5 hours the charging time is finished. The display goes out or 

the battery symbol shows a full battery. 

• Low ambient temperatures reduce the running time, high temperatures 

reduce the battery life.

• Damaged batteries must be disposed.

12. Troubleshooting

1. No laser beam - check power supply. Low battery?
2. Low range - clean laser beam exit window.
3. Laser beam blinks slowly - move device into the levelling range by tilting forwards.
4. Laser beam and direction limitation symbol blink slowly - reset laser from the

limitation.

5. Laser beam + banking arrows blink slowly - twist laser in direction of arrow until

the arrows are no longer seen.
If the errors of point 3, 4 and 5 are not corrected within 2.5 minutes, the device is
switched off automatically.

6. Laser switched off automatically (kick guard) - switch on the device again.

13. Maintenance

The laser requires no special maintenance. Keep the electrical connections clean. 
Do not clean with water spray. Clean glass parts with a soft, clean cloth. Store dry. 
Always transport the laser in its original case. 

1

2

3

4

5

6

7

8