All functions are identical to those in the horizontal position with following exceptions:
In SOPE mode the X axis can be set manually, the Z axis is automatically self-levelled. The TILT
and / or V-W-S function can be activated. If a slope has been set in the X axis and the laser is tempo-
rarily powered off, the axis will retain its original position when the laser is powered on again.
In MAN mode both (X and Z) axes can be set manually.
The TILT and V-W-S function cannot be activated. If a slope has been set in the X and Z axes and the
laser is temporarily powered off, the X axis will retain its original position when the laser is powered on
again but the Z axis will self-level.
Set up the laser in the horizontal position first to re-set the self-levelling position.