19
EN
MANUAL FUNCTION / SLOPE SETTING
The MANUAL function can only be executed with the remote control.
The laser is powered off. Press the MAN button to start the MAN function. The MAN LED is illuminated. Press
the button „select SLOPE axis (X/Y)“ to select the SLOPE axis. Then press the arrow buttons >/< and >>/<<
to adjust the level of the laser line. Confirm with ENT.
Slope setting by means of the arrow buttons
> COARSE: press the arrow button at any 1 x = one 3-mm-step in a distance of 15 m
>>FEIN: press the arrow button at any 1 x = one 1-mm-step in a distance of 15 m
Press the MAN button again to quit the MANUAL function.
With the ON/OFF button only the laser can be powered on or off.
Keypad remote control
MAN button
Select SLOPE axis
Arrow buttons SLOPE:
> in coarse steps
>> in fine steps
ON/OFF LED
ENTER button
ON/OFF button
DEACTIVATION OF THE REMOTE CONTROL FUNCTION
The remote control function can be deactivated at the laser.
Using this function the laser will work autarkical and the level set cannot be disturbed from outside, i. e. by
frequencies of other lasers working on the same site.
Keep button "P" at the laser pressed, the LED starts blinking, the remote control function is deactivated.
(Do not confound with the pulse function (receiving mode): in this mode the LED is illuminated