6

MAINTENANCE CHART 

Regular maintenance is most important for the best performance and safe operation. 

 

 

Item

 

 

remarks

 

Pre- 

Operati

-on 

check 

(daily)

 

Initial  

month 

or 20 

Hr 

Every 

months 

or 50 

Hr 

 

Every 6 

 months 

or  

100Hr 

Every  

12 

months 

or 

300Hr 

Spark Plug

 

Check condition adjust 

gap and clean. Replace 

if necessary.

 

 

 

z

 

 

 

 

Air Filter

 

Clean. Replace if   

necessary. 

 

 

z

 

 

 

 

Fuel Filter

 

Clean fuel filter.Re- 

Place if necessary. 

 

 

 

z

 

 

 

Fuel Line 

Check fuel hose for 

crack or damage Re- 

place if necessary. 

z

 

 

 

 

 

 

Check for leakage   

Retighten or replace 

gasket if necessary 

 

z

 

 

 

 

 

 

Exhaust  

System

 

Check muffler screen. 

 

 

 

z

 

 

 

Carburetor

 

Check choke 

operation. 

z

 

 

 

 

 

 

Cooling  

system

 

Check fan damage. 

 

 

 

 

z

 

 

Starting  

system

 

Check recoil   

starter operation. 

z

 

 

 

 

 

 

Decarboniz

ation

 

Clean more frequently 

if  

necessary, 

 

 

 

 

z

 

 

Fittings/Fas

teners 

Check all fittings 

and fasteners correct if 

necessary. 

 

 

 

z

 

 

 

 

AIR FILTER

 

Summary of Contents for 950W Series

Page 1: ...fore attempting to assemble install operate or maintain the product described Protect yourself and others by observing all safety information Failure to comply with the user manual could result in per...

Page 2: ...1 CONTENTS 1 SAFETY INFORMATION 2 2 CONTROL FUNCTION 2 3 PRE OPERATION CHECK 3 4 OPERATION 4 5 PERIODIC MAINTENANCE 5 6 STORAGE 6 7 SPECIFICATIONS 7 8 GENERATOR SCHEME DIAGRAM 8...

Page 3: ...he machine be sure it is kept upright If it tilts fuel may leak from the carburetor or fuel tank ENGINE AND MUFFLER MAY BE HOT z Place the machine in a place where pedestrians or children are not like...

Page 4: ...atically when the load exceeds the generator rated output PRE OPERATION CHECK NOTE Pre operation checks should be made each time when the generator is used WARNING The engine and muffler will be very...

Page 5: ...flame cigarettes etc away Ventilate when charging or using in closed space Always cover eyes when working near batteries Keep out of reach of children OPERATION STARTING THE ENGINE NOTE z Before star...

Page 6: ...tus z Reduce the load to within specified generator rated output if the AC breaker N F B turns off DC OUTPUT NOTE Battery charging if equipped Red lead to positive black to negative CAUTION This batte...

Page 7: ...ilter Clean Replace if necessary z Fuel Filter Clean fuel filter Re Place if necessary z Fuel Line Check fuel hose for crack or damage Re place if necessary z Check for leakage Retighten or replace ga...

Page 8: ...031in FUEL TANK FILTER Clean with solvent Wipe off WARNING Be sure the tank cap is tightened securely TROUBLESHOOTING ENGINE WON T START 1 Fuel systems No fuel supplied to combustion chamber z No fue...

Page 9: ...l starter until you feel compression Stop pulling Clean exterior of the generator and apply a rust inhibitor Store the generator in a dry well ventilated place with the cover place over it The generat...

Page 10: ...e Mixed oil brume lubrication Fuel No 90 gasoline Oil No Purpose oil for 2 stroke Starting Manual starting Output Mode Horizontal cone shaped shaft output Ignition C D I z Specifications subject to ch...

Page 11: ...10 SC Stator Auxiliary Winding...