TECHNICAL SUPPORT:
1.800.283.5936 (USA) OR 1.801.974.3760
APPLICATIONS •
BRIDGED OUTPUT
13
Bridged Output
NOTE: Channels configured
for 70V output cannot be
bridged.
✍
CHANNEL 1
CHANNEL 2
CHANNEL 3
CHANNEL 4
CHANNEL 5
CHANNEL 6
CHANNEL 7
CHANNEL 8
OUTPUT CHANNEL 3
OUTPUT CHANNEL 1
OUTPUT CHANNEL 2
OUTPUT CHANNEL 4
OUTPUT CHANNEL 5
OUTPUT CHANNEL 6
OUTPUT CHANNEL 7
OUTPUT CHANNEL 8
SIGNAL
CLIP 1
SIGNAL
CLIP 2
VOLUME
2
VOLTAGE 110V 5A
FREQUENCY 60Hz
VOLUME
1
70V /CH1 8Ω / CH 1
70V /CH 2 8Ω / CH 2
70V /CH 3 8Ω / CH 3
70V /CH 4 8Ω / CH 4
70V /CH 5 8Ω / CH 5
70V /CH 6 8Ω / CH 6
70V /CH 7 8Ω / CH 7
70V /CH 8 8Ω / CH 8
70V /CH1 8Ω / CH 1
70V /CH 2 8Ω / CH 2
70V /CH 3 8Ω / CH 3
70V /CH 4 8Ω / CH 4
70V /CH 5 8Ω / CH 5
70V /CH 6 8Ω / CH 6
70V /CH 7 8Ω / CH 7
70V /CH 8 8Ω / CH 8
VCR
12
3
4
5
7
6
8
0
-4
-10
-30
+4
+8
+12
System
Meter
Mic On
Inputs
Outputs
Routing
Enter
Esc
+
-
+
-
16Ω
16Ω
Gain
Adjust
Amber
No
function
+
-
8Ω
4Ω
+
-
4Ω
-
+
SIGNAL
CLIP 3
SIGNAL
CLIP 4
VOLUME
2
VOLUME
1
BRIDGE 1
SIGNAL
CLIP 5
SIGNAL
CLIP 6
VOLUME
2
VOLUME
1
BRIDGE 1
SIGNAL
CLIP 7
SIGNAL
CLIP 8
VOLUME
2
VOLUME
1
BRIDGE 1
Zone 2 — Series
Zone 3 — Parallel
Zone 1
Figure 5. Typical Bridged Output
Configuration
Channel pairs 1-2, 3-4, 5-6, and 7-8 may be bridged in a one-channel
input/two-channel output configuration for a maximum of 50 watts of
output power— into 8 Ohms—per bridged channel pair. Ensure that the
Molex plug is in the 8 Ohm receptacle for each bridged pair.
Figure 5 (below) shows a balanced input/bridged output configuration.
After you make the appropriate connections for bridging both channels,
insert the Molex plug into the 8 Ohm receptacle and slide the bridge
switch for the channel pair to the right (ON). The amber LED next to the
switch will indicate that bridging is active.
Plug Molex
plugs into 8Ω
receptacles