usE aND opERatIoN

pLaCEs oCCupIED bY authoRIZED opERatoRs

The Authorized operators, depending on the type of manual intervention required, must take 

the places shown in Fig. 1.

THE AUTHORIZED OPERATORS ACCORDING TO THE PLACE OCCUPIED, ARE 

obLIgED to pERfoRm thE REQuIRED aCtIoNs DEsCRIbED IN thE RELa-

tED sECtIoNs.

pLaN VIEW

authoRIZED opERatoRs pLaCE DEsCRIptIoN of INtERVENtIoN

aLL

With the consent of the Supervisor, execute on 

the machine lifting operations, maintenance 

operations, handling and use of the machine.

Summary of Contents for CLINIC 1.25

Page 1: ...Instruction Manual Compressors CLINIC 1 25 CLINIC DRY 1 25 CLINIC 3 25 CLINIC DRY 3 25 EN...

Page 2: ......

Page 3: ...ensions of the machine 18 Technical data 19 Intended use of the machine 20 Source of energy supply 20 Products used for the operation 21 Phases of operation 21 Reasonably foreseeable misuse 21 Transpo...

Page 4: ...ave INFORMATION TO THE CUSTOMER DOCUMENT PAGE TO DO STATEMENT OF DELIVERY OF THE INSTRUCTION MANUAL 5 The authorised operators must complete and sign to confirm the delivery and rea ding of the instru...

Page 5: ...__________ ____________________________________________ Mr _______________________________________ __________ ____________________________________________ Mr _______________________________________ __...

Page 6: ...____________________________________________________________________________ At the presence of the entrusted operator Mr ______________________________________________________________________________...

Page 7: ...ast 2014 30 UE Directive of the European Parliament and of the Council of 26 February 2014 replacing 2004 108 EC Directive of the European Parliament and of the Council of 15 December 2004 on the appr...

Page 8: ...ICAL DATA The CE marking Fig 1 of the machine indicates compliance with the essential occupatio nal health and safety rules set forth by the European Directives listed in the Declaration of CE Conform...

Page 9: ...stand all parts of this manual and adhere strictly to the rules herein described in order to assure their own and others safety the best performance of the machine and ensure the maximum efficiency a...

Page 10: ...ion to take action Generic prohibition sign It highlights the prohibition to perform an action Danger Sign EX It highlights the risk due to explosion CONSULTATION NOTES STATE MACHINE OFF Before perfor...

Page 11: ...the turning off of the machine and in total respect of the instructions in this ma nual equipped with personal protective equipment PPD specified and occupying the pla ces see related paragraph OPERAT...

Page 12: ...ction devices PPD envisioned and occupying the positions described see related paragraph SAFETY REPRESENTATIVE It is a qualified engineer appointed by the customer in possession of technical and profe...

Page 13: ...par Paragraph Pos Position Rif Reference sec Seconds L Left TAB Table see SEE ALL RIGHTS RESERVED The reserved rights related to this instruction manual are in possession of the manufacturer All infor...

Page 14: ...gentilincompressors com within seven days of purchase and b have completed the registration form completely and accurately filling in the required fields with exact complete and true information and h...

Page 15: ...model names and specifications that distinguish them MODEL DESCRIPTION CLINIC 1 25 Oil free air compressor with 25 litres tank without dryer CLINIC DRY 1 25 Oil free air compressor with 25 litres tan...

Page 16: ...omponents that make up the machine KEY 1 Support feet 2 Non return valve 3 Single cylinder pumping unit 4 Electric motor 5 Restorable circuit breaker 6 Air intake filters 7 Dryer filter 8 Air tank 9 C...

Page 17: ...17 www gentilinair com CLINIC 3 25 CLINIC DRY 3 25 15 8 7 4 16 13 16 11 1 10 14 4 14 11 16 1 12 10 13 6 15 8 9 2 6 5 17 2 9 12 5 17 Instruction Manual Compressors Clinic MAN1325001 07 2019...

Page 18: ...C Fig 1 Instruction Manual Compressors Clinic MAN1325001 07 2019 DIMENSIONS OF THE MACHINE Tab 1 gives the clearance of the machine represented in Fig 1 MODELS A B C CLINIC 1 25 697 mm 420 mm 420 mm...

Page 19: ...Noise dB A 64 64 64 Weight Kg 30 5 31 5 36 Ambient temperature C 0 40 0 40 0 40 Service class 70 70 70 Motor rotation direction The compressor can be used in both directions of rotation CLINIC DRY 1 2...

Page 20: ...t temperature C 0 40 0 40 0 40 Service class 100 100 100 Motor rotation direction The compressor can be used in both directions of rotation CLINIC DRY 3 25 Power supply 230V 50 Hz 230V 60 Hz 110V 60 H...

Page 21: ...ACHINE WARNING YOU MUST KEEP THE MACHINE OUT OF REACH OF UNAUTHORIZED PERSONS INTENDED USE Compressed air production to operate dental tools OPERATORS IN CHARGE FOR USE An authorized operator with the...

Page 22: ...USE HAVING THE CHARACTERISTICS INDICATED ON PAR INTENDED USE OF THE MA CHINE IT IS COMPULSORY TO USE THE MACHINE IN THE RESPECT OF THE LEGISLATION IN FORCE IN THE COUNTRY OF USE CONCERNING INTRODUCTIO...

Page 23: ...its own personnel and appropriate means in compliance with the regulations shall ensure the operations of packaging lifting loading transport and unloading in relation to the type of transport land s...

Page 24: ...ILITY OF LOAD 1 Insert the forks 2 Fig 1 under the pallet 1 keeping them at the centre of the latter 2 Raise the packaging 3 a few centimetres to make sure the load is actually centred in the forks 3...

Page 25: ...USING A SUITABLE MEAN E G TRAN SPALLET IN ACCORDANCE WITH THE REGULATIONS ON THE MANUAL HANDLING OF LOADS IN ORDER TO AVOID ADVERSE CONDITIONS THAT INVOL VE RISK OF ERGONOMIC INJURIES TO THE BACK The...

Page 26: ...on a flat floor that ensures stability in relation to the overall dimensions and to the weight IN ORDER TO ENSURE THAT THE AUTHORIZED OPERATORS OCCUPY THE WORK POSITIONS EXPECTED IT IS MANDATORY TO E...

Page 27: ...RE ADY FOR THE OPERATION PNEUMATIC CONNECTION THE MANUFACTURER HAS NO LIABILITY FOR INJURY TO PERSONS ANI MALS AND OR THINGS RESULTING FROM FAILURE TO OBSERVE THE WAR NINGS DESCRIBED ABOVE IT IS STRI...

Page 28: ...ELECTRIC CUTTING DEVICE WITH A SUITABLE DISCONNECTING PROTECTION COORDINATED WITH THE GROUNDING PLANT ANY TYPE OF ELECTRIC MATERIAL USED FOR THE CONNECTION MUST BE SUITA BLE FOR USE MARKED CE IF SUBJ...

Page 29: ...the system if the pressure switch for any problems does not function The intervention of the safety valve forces the operator to turn off the machine and request the assistance of the maintenance per...

Page 30: ...3 2 4 CLINIC DRY 1 25 1 4 3 2 Instruction Manual Compressors Clinic MAN1325001 07 2019 IT IS FORBIDDEN TO MANIPULATE EXCLUDE REMOVE AND OR REPLA CE ANY SAFETY DEVICE IN THIS MACHINE IT IS ABSOLUTELY F...

Page 31: ...forbidden and not reasonably foreseeable PROBABILITY Low and accidental STAGE WHERE THERE IS A RISK During use and operation MEASURES TAKEN Safety signs Compulsory use of personal protective equipmen...

Page 32: ...ILITY IT IS COMPULSORY TO REPLACE THE SAFE TY SIGNS DETERIORATED BY REQUESTING THEM TO THE MANUFACTURER AND OR AU THORIZED DEALER RESIDUAL RISK N 2 DANGER OF CRUSHING FOOT DUE TO ACCIDENTAL FALL FROM...

Page 33: ...ures USE AND OPERATION PLACES OCCUPIED BY AUTHORIZED OPERATORS The Authorized operators depending on the type of manual intervention required must take the places shown in Fig 1 THE AUTHORIZED OPERATO...

Page 34: ...ar max 8 bar fitted onto the pneumatic plant It is used to control the automatic start of the machine when the pressure drops to 6 bar and the automatic stop when the pressure reaches 8 bar 4 Interrut...

Page 35: ...35 www gentilinair com CLINIC DRY 3 25 3 2 5 CLINIC 3 25 5 2 3 CLINIC 1 25 5 2 3 CLINIC DRY 1 25 3 5 2 4 4 4 4 Instruction Manual Compressors Clinic MAN1325001 07 2019...

Page 36: ...the condensate drain valve is closed 9 6 Use the Personal protective equipment PPE required 7 Make sure you have read and understood all parts of this Instruction Manual 8 Make sure that after last us...

Page 37: ...the machine runs up to the max operating pressure at 8 bar and then stops automatically RESETTABLE THERMAL If there is an overload and or a short circuit in the electrical system of the machine the o...

Page 38: ...achine 3 Only in case of work cycle end perform the condensate discharge from the tank acting on the condensate drain valve 9 EMERGENCY STOP The Emergency Stop of the machine can be done by bringing i...

Page 39: ...switch 14 in pos OFF 0 2 If necessary repeat the operations described in par TURNING ON THE MACHINE INTERVENTION ON THE SAFETY VALVE In the event of a malfunction of the pressure switch and the press...

Page 40: ...ng properly and inserted into the socket Check that any extension cords used and the current outlet are operatio nal Check that the switch of the main po wer supply is functioning and in pos ON I The...

Page 41: ...ns of use and operationofthemachine throughvarioustypesofintervention adjustments visual inspection recovery levels etc performed by the maintenance tech nician or by the manufacturer s technician at...

Page 42: ...s below 1 Place under the condensate drain valve a col lection container fit for use 2 Slowly open the valve of condensate drain 12 and wait for a complete exit of compressed air and condensate 3 Clos...

Page 43: ...the filter 3 and clean it with compressed air REPLACE THE FILTER IN CASE OF EVIDENT WEAR 4 After placing back the filter replace the cover properly 5 Indicate the action on the maintenance card YOU MU...

Page 44: ...t 24 from the lower head 5 Blow inside the pipes 11 12 and the heads 5 13 with compressed air Replace all filters 6 and the O Rings 1 4 7 8 Insert the closing cap 2 with the whole valve unit 24 in the...

Page 45: ...m the lower head 5 Remove the closing plate 3 from the lower head 5 Blow inside the pipes 11 12 and the heads 5 13 with compressed air Replace all filters 6 and the O Rings 1 4 7 8 Insert the closing...

Page 46: ...ON Upon demolition of the machine strictly follow the requirements in force in the country of demolition Proceed to the differentiation of the parts that make up the machine accord ing to the differen...

Page 47: ...ir com Instruction Manual Compressors Clinic MAN1325001 07 2019 SPARE PARTS GENUINE PARTS FOR ANY SUBSTITUTIONS MUST BE REQUIRED ONLY TO THE MANUFACTURER IT IS STRICTLY PROHIBITED THE USE OF NON ORIGI...

Page 48: ...CLINIC 1 25 Year Details Replacements Hours 1 500 2 Date Signature F2 G1 1000 3 1500 4 Date Signature F2 G1 2000 5 2500 6 Date Signature F2 G1 3000 7 3500 8 Date Signature F2 G1 4000 9 4500 10 Date Si...

Page 49: ...s Replacements Hours 1 500 2 Date Signature F2 F3 G1 1000 3 1500 4 Date Signature F2 F3 G1 2000 5 2500 6 Date Signature F2 F3 G1 3000 7 3500 8 Date Signature F2 F3 G1 4000 9 4500 10 Date Signature F2...

Page 50: ...25 Year Details Replacements Hours 1 500 2 Date Signature F2 1000 3 1500 4 Date Signature F2 G1 2000 5 2500 6 Date Signature F2 3000 7 3500 8 Date Signature F2 G1 G2 4000 9 4500 10 Date Signature F2...

Page 51: ...ements Hours 1 500 2 Date Signature F2 F3 1000 3 1500 4 Date Signature F2 F3 G1 2000 5 2500 6 Date Signature F2 F3 3000 7 3500 8 Date Signature F2 F3 G1 G2 4000 9 4500 10 Date Signature F2 F3 5000 Des...

Page 52: ...Via delle Tezze 20 22 36070 TRISSINO VI Italy phone 39 0445 96 20 00 info gentilinair com www gentilinair com Nuovo Manuale per Compressori Serie 1 25 3 25 MAN1325001 07 2019 M A N 1 3 2 5 0 0 1...