FIGURE 5: RECOMMENDED SMOKE ALARM MOUNTING LOCATIONS.

FIGURE 6: RECOMMENDED SMOKE ALARM LOCATION IN ROOMS WITH

SLOPED, GABLED, OR PEAKED CEILINGS.

The placement of the device is critical if maximum speed of fire detection is

desired. Thus, a logical location for an alarm is the center of the ceiling. At this

location, the smoke alarm is closest to all areas of the room.

WHERE SMOKE ALARMS SHOULD BE INSTALLED IN

MOBILE HOMES

In mobile homes built after about 1978 that were designed and insulated to

be energy-efficient, smoke alarms should be installed as described in the section

above.

In older mobile homes that have little or no insulation compared to today's

standards, uninsulated metal outside walls and roofs can transfer heat and cold

from outdoors, making the air right next to them hotter or colder than the rest of

the inside air. These layers of hotter or colder air can prevent smoke from

reaching a smoke alarm. Therefore, install smoke alarms in such units only on

inside walls, not more than 12 inches (30 cm) from the ceiling. If you are not

sure about the insulation level in your mobile home, or if you notice that the walls

or ceiling are unusually hot or cold, install the alarm on an inside wall.

Minimum protection requires one smoke alarm as close to the sleeping area

as possible. For better protection, install one alarm in each room, but first read

the LOCATIONS TO AVOID section of this manual.

LOCATIONS TO AVOID

Nuisance alarms are caused by placing smoke alarms where they will not

operate properly.

To avoid nuisance alarms, do not place smoke alarms:

In or near areas where combustion particles are normally present such

as kitchens; in garages

where there are particles of combustion in vehicle

exhausts;

near furnaces, hot water heaters, or gas space heaters. Install

alarms at least 20 feet (6 meters) away from kitchens and other areas

where combustion particles are normally present.

In air streams passing by kitchens.

FIGURE 7 shows how an alarm can

be exposed to combustion particles in normal air movement paths, and how

to correct this situation.

In damp or very humid areas,

or next to bathrooms with showers. The moisture

in humid air can enter the sensing chamber as water vapor, then cool and

condense into droplets that cause a nuisance alarm. Install smoke alarms at least

10 feet (3 meters) away from bathrooms.

In very cold or very hot environments, or in unheated buildings or outdoor

rooms,

where the temperature can go below or above the operating range of the

alarm. Temperature limits for proper operation are 40° to 100°F (4.4° to 37.8°C).

In very dusty or dirty areas.

Dust and dirt can build up on the smoke alarm's

sensing chamber and can make it overly sensitive, or block openings to the sensing

chamber and keep the unit from sensing smoke.

Near fresh air inlets or returns or excessively drafty areas.

Air conditioners,

heaters, fans, and fresh air intakes and returns can drive smoke away from smoke

alarms, making the smoke alarms less effective.

In dead air spaces at the top of a peaked roof or in the corners between

ceilings and walls.

Dead air may prevent smoke from reaching the device. See

Figures 5 and 6 for recommended mounting locations.

In insect-infested areas.

If insects enter a smoke alarm's sensing chamber, they

may cause a nuisance alarm.

Get rid of the bugs before installing alarms

where bugs are a problem.

Near fluorescent light fixtures.

Electrical "noise" from nearby fluorescent light

fixtures may cause a nuisance alarm.

Install units and fluorescent lights on

separate electrical circuits.

Never remove battery from the unit to silence a nuisance alarm.

Open a window or fan the air around the smoke alarm to remove the smoke. The

alarm will automatically turn off when the smoke in the air is completely gone. Do not

stand close to the smoke alarm. The sound produced by the alarm is loud because it

is designed to awaken you in an emergency. Prolonged exposure to the horn at a

close distance may be harmful to your hearing.

INSTALLATION 913 SERIES

CAUTION:

New Construction: DO NOT attach smoke alarm head until AFTER

sanding, painting, and other dust creating situations are finished and cleaned up.

MOUNTING: PLATE & ALARM

1. Remove the mounting plate from the back of the smoke alarm by rotating it

counter-clockwise until plate unsnaps.

2. Mount plate to either the wall or ceiling, see "Mounting Location" instructions. If

smoke alarm is to be placed on the wall, mount plate so the snap-in tabs are in a

vertical position.

NOTICE

: PLATE IS MARKED "THIS SIDE OUT" FOR PROPER MOUNTING.

FIGURE 7

550-0033

Page 9-4

FIGURE 5

FIGURE 6

3. To use the supplied screw anchors, drill two 3/16" holes, insert the screw anchors,

and mount the plate to wall using the supplied screws.

4. Place the smoke alarm up to the mounting plate, rotating it to about 10:00 o'clock

then rotate it clockwise to 12:00. It should "snap-lock" into place. Keep the smoke

alarm parallel to the mounting plate so upper and lower tabs on the plate seat

correctly into the smoke alarm.