![Gentec SC1202-TN User Manual Download Page 8](http://html1.mh-extra.com/html/gentec/sc1202-tn/sc1202-tn_user-manual_2213637008.webp)
Scaler Switcher with Digital Amplifier-TN (12 inputs)
3
Receiver), support PoC.
②
Four VGA connectors for VGA inputs.
③
Four HDMI connectors for HDMI inputs.
④
Four 3.5mm audio connectors for VGA audio inputs.
⑤
One Component video input: Y/Pb/Pr, two composite video inputs: C-Video, one
Separate video input: S-Video, two pairs L/R for analog audio input.
⑥
One RS232 port for series control, one USB port for firmware update.
⑦
One TCP/IP port (selectable): for network controlling.
⑧
Amplifier with 2x10W@8
Ω
output.
⑨
Connector for POWER.
⑩
Two MIC connectors: MIC with pre-amplification, LINE for audio direct input.
⑪
Grounding protection.
Note:
Pictures shown in this manual are for reference only, different model and
specifications are subject to real product.
TCP/IP port and HDBT port are selectable. When there is a TCP/IP port, the
switcher may be named as Scaler Switcher with Digital Amplifier-N. When there is
a HDBT port, the switcher may be named as Scaler Switcher with Digital Amplifier-
T.
For example, the name “Scaler Switcher with Digital Amplifier-TN” suggests that
the switcher has both the two port. While “Scaler Switcher with Digital Amplifier”
suggests that the switcher has neither a TCP/IP port nor a HDBT port.
3. System Connection
3.1. Usage Precautions
1)
System should be installed in a clean environment and has a prop temperature and
humidity.
2)
All of the power switches, plugs, sockets and power cords should be insulated and
safe.
3)
All devices should be connected before power on.
3.2. System Diagram