*Regular service must be carried out on the product to avoid product failure.

6.  Tighten using flats on trigger spray and 

flats on the Hose

7.  Turn on the Water and test the unit.

Trigger Spray Fixing Methods

Using Teflon Tape

•  Apply adequate Teflon tape to the male 

thread of the trigger spray.

•  Screw hose connection on to trigger 

spray then tighten firmly against "O" 

Ring Supplied on trigger.

Using Loxeal

•  Insert the white teflon washer into the 

hose adaptor.

•  Apply Loxeal to the male thread of the 

trigger spray.

•  Screw hose connection on to trigger 

spray then tighten firmly against oring. 

Test to ensure there are no leaks.

1. 

Fit the flat washer (24) into the top of the 

Riser to ensure a water tight seal.

2.  Slide the spring (1) to expose the male 

connecting thread (2).

3.  Using the correct spanner, screw the male 

thread of the flexible hose into the top 

of the riser. Do up firmly but do not over 

tighten. 

Support the weight of the 

hose and spring while tightening to 

prevent cross threading and kinking 

of the hose. 

4.  Slide the spring back over the end of the 

hose until it sits on top of the Riser.

Apply Teflon tape or loxeal to the male thread 

of the trigger spray. 

5.  Screw the Trigger Spray Unit (41) to the  

Hose, tighten firmly using a spanner on the 

flat section of the Nut. 

SPRING AND TRIGGER SPRAY INSTALLATION

FOR ALL UNITS

Summary of Contents for JETF 5600

Page 1: ...NSTALLATION MANUAL PRE RINSE UNITS Hob Mounted Units JETF1200 JETF1200C JETF1200LP JETF4000 JETF6000 JETF9900 Wall Mounted Units JETF3000 JETF3000W JETF5000 JETF 5600 Hand Held Units JETF7000 JETF7500...

Page 2: ...4 Technical Drawings 6 Unit Components 12 Hob Mounted Units Installation 14 Wall Mounted Units Installation 15 Wall Bracket Installation 16 Spring and Trigger Spray Installation 17 Maintenance and Be...

Page 3: ...t 5 star 6 litres per minute The more stars the more water efficient WATER RATING www waterrating gov au Licence No 1334 GENTEC AUSTRALIA In accordance with AS NZS 6400 4 5litres per minute spray tap...

Page 4: ...HOB MOUNTED PRE RINSE UNIT LESS POT FILLER COMPACT HOB MOUNTED PRE RINSE UNIT JETF3000 JETF3000W JET5600 WALL MOUNTED PRE RINSE UNIT LEVER CONTROL VALVES COMPACT WALL MOUNTED PRE RINSE UNIT WALL MOUNT...

Page 5: ...com au 5 JETF6000 JETF4000 JETF9900 HOB MOUNTED PRE RINSE UNIT HOB MOUNTED PRE RINSE UNIT HOB MOUNTED PRE RINSE UNIT JETF5000 JETF7000 JET7500 WALL MOUNTED PRE RINSE UNIT HAND HELD PRE RINSE UNIT HAND...

Page 6: ...Drawings JETF1200 HOB MOUNTED PRE RINSE UNIT JETF1200C COMPACT HOB MOUNTED PRE RINSE UNIT 250 55 7 111 205 950 550 350 60 105 245 8 279 128 37 5 53 81 280 250 128 38 105 60 56 111 119 5 53 58 400 165...

Page 7: ...F4000 HOB MOUNTED PRE RINSE UNIT JETF5000 WALL MOUNTED PRE RINSE UNIT 246 445 250 250 56 18 54 34 9 42 17MAX 40 92 103 140 173 22 38 128 400 205 1016 45 30 62 10 34 280 479 250 28 64 135 56 18 173 207...

Page 8: ...ES JETF3000W COMPACT WALL MOUNTED PRE RINSE UNIT 45 30 62 10 34 280 479 250 28 64 135 56 18 173 207 22 256 205 250 128 38 400 54 34 10 42 17MAX 40 92 103 987 45 30 62 10 34 64 54 34 9 42 17MAX 40 92 1...

Page 9: ...TED PRE RINSE UNIT JETF9900 HOB MOUNTED PRE RINSE UNIT 22 42 30 215 40 65 6 20 45 30 82 65 321 520 250 56 18 167 215 22 351 300 250 128 38 400 1023 246 400 140 445 173 28 22 256 205 250 56 18 250 128...

Page 10: ...ge Ceramic Disc Cartridge Min Continuous Flow Working Pressure 150kPa 150kPa RecommendedStatic Working Pressure 350kPa 350kPa Min Continuous Working Temperature 5 C 5 C Max Continuous Working Temperat...

Page 11: ...rome Chrome Chrome Chrome Chrome Chrome Polished Polished Polished Polished Polished Polished Polished Brass Brass Brass Brass Brass Brass Brass Ceramic Disc Cartridge Ceramic Disc Cartridge Ceramic D...

Page 12: ...12 Unit components Wall Mounted Unit Components Bench Mounted Unit Riser...

Page 13: ...JETF0065 Handle Kit 21 Body 1 22 Cap 1 23 JETF0068 O Ring Kit for Pot Filler 1 24 JETF9005 Fibre Washer 1 No Code Description Qty JETF0052 O Ring Service Kit for Trigger Spray Gun JETF0074 Fixing Scr...

Page 14: ...UNTED UNITS JETF1200 JETF1200LP JETF4000 JETF9900 Installation Instructions 4 From underneath the counter top slide on the U shaped washer then the U shaped fixing plate 34 35 5 Screw on the hex nuts...

Page 15: ...hread 5 Insert the pre rinse body 15 into the wall base arm 42 and tighten the Grub Screw 18 back in place Wall Handles Installation 6 Unscrew the cover flange 50 from the main body of the cartridge 1...

Page 16: ...ack to the wall Tighten the brass nut and olive ensuring a firm and solid installation Slide the chrome cover plate over the wall plate Note For a stainless steel splashback and or cool room panel wal...

Page 17: ...spray then tighten firmly against oring Test to ensure there are no leaks 1 Fit the flat washer 24 into the top of the Riser to ensure a water tight seal 2 Slide the spring 1 to expose the male conne...

Page 18: ...ebris damaging the cartridges Ensure the wall bracket is firmly attached to the wall to reduce strain on the riser and mixer fixings Reduce strain on the product by installing a pressure limiting valv...

Page 19: ...cartridge in the pot filler Pot Filler and Trigger Spray must be turned off when not in use A damaged cartridge needs to be replaced 1 Can I take the tap out and fix it myself I ve tried fixing it mys...

Page 20: ...l bracket is designed to support the riser so removing it or extending it will put extra pressure on the riser and lead to leaks from the riser and or bottom mixer For more details on the Wall Bracket...

Page 21: ...ged defect in a reasonable time 2 2 8 completed credit card authorisation in the form set out in Schedule 2 to these conditions accepting liability in accordance with clause 2 6 if the product is not...

Page 22: ...law the Principal 4 2 1 excludes all implied warranties and conditions under statute or general law as to merchantability description quality suitability fitness for purpose or otherwise 4 2 2 is not...

Page 23: ...ime is not a Business Day or is after 5pm on a Business Day in which case that communication will be deemed to have been received at 9am on the next Business Day 5 2 3 if emailed at the local time in...

Page 24: ...info gentecaustralia com au www gentecaustralia com au Unit 6 20 28 Ricketty St Mascot Sydney NSW 2020 P 612 9319 4422 F 612 8088 7635 MAR IM JETF01 ZH 250321...

Reviews: