background image

Page 

4

 of 

7

 

5.

 

Power supply in Setting State now. 

Press “RUN/STOP” button, it will enter into Operating State.

 

EDIT [ 0 ] 

RUN! 

00:01

 

U = 100V 

   

100v 

I = 500mA 

   350mA 

P = 300W 

   35w 

6.

 

Power supply in Operating State now. 

Press “RUN/STOP” button,

 it will stop output and return 

to Setting State. 

7.

 

In Setting State, continue to press “EDIT” button, it

 will enter into Editing State and display: 

“SAVE [□]” → “LOAD [□]” → “T= □□:□□” → “QUIT” → “SAVE [□]”…

 

EDIT [ 0 ] 

 

U = 100V 

0v 

I = 500mA 

0mA 

P = 300W 

0w 

8.

 

At “SAVE □”, press “

or “

 button to select number of memory program. The range of 

number is from 1 to 9. Then press “ENT

 button to save current method into this program. 

9.

 

At “LOAD [□]”, press “

 or “

 button to select number that needed. The range of number is 

from 1 to 9. Then press “ENT

 button to load the current method from program. 

10.

 

At “T= □□:□□”, press “

or “

 button to set operating time. 

11.

 

The range of timer is from 1min to 99hs and 59mins. Then press “ENT” button to save

 it. 

EDIT [ 0 ] 

 

U = 100V 

0v 

I = 500mA 

0mA 

P = 300W 

0w 

 

12.

 

At “QUIT”, press “ENT” button to quit Editing

 state, and return to Setting State.

 

ERROR ALARM 

1.

 

When the power supply run with Over-load, it will stop automatically and alarm with buzzer, 
then display 

“ERROR 1!”.Turn off the switch

 immediately. 

2.

 

When the power supply run with No-load, It will stop automatically and alarm with buzzer, then 
display 

“ERROR 2!”.Turn off the switch

 immediately. 

 

 

Summary of Contents for BT Lab Systems BT407

Page 1: ...A Geno Technology Inc USA brand name 1 800 628 7730 1 314 991 6034 info BTLabSystems com Universal Power Supply 300V Cat No BT407 ...

Page 2: ...CIFICATIONS 3 CHARACTERISTIC FEATURES 3 SETUP AND OPERATION 3 ERROR ALARM 4 WARNING 5 IMPORTANT 5 ENVIRONMENTAL CONDITIONS 5 AVOIDING ELECTRICAL SHOCK 6 AVOIDING DAMAGE TO THE INSTRUMENT 6 EQUIPMENT OPERATION 7 WARRANTY 7 TECHNICAL SUPPORT 7 ...

Page 3: ... constant voltage constant current constant power incorrect operation fault intelligent prompt functions Automatic detection of no load over load short circuit rapid resistance change ground leak and system overheating SETUP AND OPERATION 1 Turn on the power switch enter into Setting State EDIT 0 U 100V 0v I 500mA 0mA P 300W 0w 2 The cursor will flash at U V Set the value of constant voltage by pr...

Page 4: ...o save current method into this program 9 At LOAD press or button to select number that needed The range of number is from 1 to 9 Then press ENT button to load the current method from program 10 At T press or button to set operating time 11 The range of timer is from 1min to 99hs and 59mins Then press ENT button to save it EDIT 0 U 100V 0v I 500mA 0mA P 300W 0w 12 At QUIT press ENT button to quit ...

Page 5: ... of the power supply 4 When taking the power supply into a cold room the unit can be operated immediately However when removing the power supply from the cold room let the unit equilibrate to room temperature for a minimum of 2 hours before using it 5 Never connect a high voltage output lead to earth ground This defeats the floating electrical isolation of the power supply and exposes the user to ...

Page 6: ... cord to a properly grounded AC outlet AVOIDING DAMAGE TO THE INSTRUMENT 1 Do not attempt to operate the device if damage is suspected 2 Protect this unit from physical damage corrosive agents and extreme temperatures direct sunlight etc 3 For proper ventilation and safety concerns keep at least 10 cm of space behind the instrument and at least 6 cm of space on each side 4 Use high level of precau...

Page 7: ...d workmanship under normal service for one year from the shipping date to purchaser This warranty excludes damages resulting from shipping misuse carelessness or neglect BT Lab Systems s liability under the warranty is limited to the receipt of reasonable proof by the customer that the defect is embraced within the terms of the warranty All claims made under this warranty must be presented to BT L...

Reviews: