Works with 50A parallel kits

This parallel kit is intended to be used only with GENMAX inverter generators. 
Please read safety information below before proceeding.

1. Make sure both engine switches are in the off position, and confirm the 

    Low idle switches on both generators are turned off.

2. Connect the black and red parallel cable leads to the black parallel ports 
    on each corresponding inverters control panel. DO NOT connect two red 
    leads or two black leads into the same inverter.

3. Attach the ground terminal (green wire) from each end of the parallel 
    cable to the corresponding ground terminal on each generator.Connect 
    and tighten the ground wire.

4. Start each generator and confirm that the green output indicator is 

    illuminated on both.

5. If using Low idle mode, turn both Low idle switches on after the 
    generators are started.

6. To shut down, turn off both generators and then remove the parallel 
    cords.

Installation and Operation:

Operating a generator can be dangerous if used improperly. 

Always refer to owners manual for safe and proper operation of 

the generator.

R

Inverter Parallel Kit Operation

WARNING

MODLE: GM9000PK