OPERATING INSTRUCTIONS FOR PRIME RANGE 

 

1. 

UNPACKING 

1.1 

Remove all packing material from between the shelves and inner walls of the oven. 

 
 

2. 

MAINS SUPPLY

 

2.1 

240-volt units.  

Each unit comes supplied with a mains connection lead already fitted with 

a  correctly  rated  fuse.    The  fuse  rating  and  other  details  for  each  unit  is  shown  on  the 
voltage  plate  riveted  to  the  back  of  the  unit.    It  is  important  that,  if  the  fuse  needs  to  be 
replaced, it must only be replaced with one of the correct rating. 

 

2.2 

110-volt units

 are supplied with a cable but without a plug or fuse.  These units should be 

wired in by a suitably qualified electrician to the following:- 

BROWN 

‘L’ Live pin 

Refer to voltage plate 

BLUE 

‘N’ Neutral pin 

for fuse requirement 

GREEN/YELLOW  ‘E’ Earth pin 

 

WARNING 

DO NOT CONNECT THE OVEN TO A D.C. MAINS SUPPLY OR 

SERIOUS DAMAGE WILL OCCUR 

 
 
 
3. 

OPERATION – Standard Control 

 

3.1  Position the shelves within the work chamber. 

3.2  Switch ‘ON’ the mains switch, indicated by lighting up green. 

3.3  If unit is already in use press the ‘start/stop button       ’  to extinguish the amber lamp. 

3.5  Press and hold the ‘temperature button        ’ for 2 seconds. 

3.5  The  ‘setpoint  display’  will  continue  to  show  the  setpoint  as  it  is  edited.  The  ‘temperature’ 

display will show “S” to indicate the setpoint is being edited. 

3.6  Use  the  increment            and            decrement  buttons  to  set  the  desired  temperature  in  one 

degree steps. 

3.7  When no keys have been pressed for 10 seconds, or if the `temperature button         ’       is 

pressed again, the new value will be stored and the temperature display will return to normal. 

3.8  Set the ‘overheat dial’ to approximately 10 to 15 degrees above your set point.             Refer 

to Page 6 for Overheat Scaling. 

3.9  Press the ‘Overheat reset’ button to energise the overheat circuit   

3.10  Press the ‘start/stop button       ’ 

 