Solar energy charge/discharge LED indicator state introduction

LED display

Introduction

Solar

Green

Light

Charge controller is in charging...

Twinkle

Charging controller to prepare...

Extinguish

Charge controller is in standby...

Battery

Green

/Red

two

tone

Red quick

flashing

Battery voltage high voltage reminder

;>

16V

Green quick

flashing

Battery voltage charge protection

;>

13.8V

Green light

Battery voltage normal

Orange

Red+gree

n light

Battery voltage low voltage reminder

<11.6V

Red light

Battery voltage under-voltage protection

reminder

<11.1V

DC

Output

Yello

w

Quick

flashing

DC load current overload or short circuit

Light

DC output voltage normal

Twinkle

DC load current overload

Extinguish

Power off DC output

5

Inverter LCD display/ operation introduction

LCD display and function key operation interface can display the

equipment working state, such as: input/output voltage, frequency, the mains
supply mode, inversion mode, battery capacity, loads capacity, alarming
reminder etc.

-5-

6

Panel key function/LCD setup introduction

Function key

Operation introduction

Mute

key

Long press for 1 second, buzzer once, stars mute

state

Long press 1 second, buzzer twice, close mute state

Functi

on key

Long press 5 seconds, can choose 01, 02, 03 mode

cycle, after the selected mode, the machine will

restart to take effect;

The mains

supply preferred

mode

Energy-saving

mode

Battery preferred

mode

ON/OF

F

Starti

ng up

Long press for 2 seconds, release after buzzer

once, equipment starts output

Powe

r off

Long press for 2 seconds, release after

internal actuating of relay, equipment close

output

7

LCD display introduction

-6-

Summary of Contents for JLS-ESS2-2kwh

Page 1: ...installation use and troubleshooting and important information and advice Please properly keep this manual Contents 1 Product Features 1 2 Installation and Storage instructions 1 3 Product appearance...

Page 2: ...sories is complete including a host controller a user manual 2 Check whether the device is damaged in transit if you find damaged please do not start machine and inform your shipper and dealer 2 Insta...

Page 3: ...built in battery switch RS232communication port Model stickers Heat dissipation window 3 Front panel introduction Instructions Inverter LCD display operation interface Solar Solar input state indicato...

Page 4: ...DC output 5 Inverter LCD display operation introduction LCD display and function key operation interface can display the equipment working state such as input output voltage frequency the mains suppl...

Page 5: ...e Battery voltage 12V A pcs Twinkle 10 5V A Light 10 5 11 2V A Light 11 2 11 6V A Light 11 6 12 1V A Light 12 1 12 5V A Light 12 5V A 7 Load icon introduction LCD display Function introduction Output...

Page 6: ...ar charging system after adequate electricity equipment automatically converted to battery energy through internal module into high quality electricity for load When the battery power down to low volt...

Page 7: ...DC load working current can t exceed the equipment rated current the two 15 12VDC Output DC terminal port on the front panel foreign respectively with 12 VDC 1 amp current two 16 5 VDC Output dc port...

Page 8: ...ck in order to avoid batter deep discharge loss built in controller has power loss when standby 13 7 Simple fault judgment and processing Warning Internal of the machine has high pressure Don t open i...

Page 9: ...protection VDC 28 4 Voltage for overcharge recovery VDC 28 0 Voltage for floating charge VDC 27 4 DC outp ut Voltage for high voltage protection VDC 32V High voltage recovery voltage VDC 30 4 Low vol...

Reviews: