BRAIN 17
12
732788 - Rev. A_1
BUS G-WAY
ENGLISH
Address assignment of BUS G-WAY photocells
To assign the address to each pair of photocells, you must set the Dip-Switches (
DS1
) located on the
transmitter and corresponding receiver.
The transmitter and receiver of a pair of photocells must have the same
DIP-SWITCH setting.
Two or more pairs of photocells must not have the same DIP-SWITCH setting.
Dip1
Dip2
Dip3
Dip4
TYPE OF PHOTOCELLS
OFF
OFF
OFF
OFF
OPENING (max 6 pairs)
OFF
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
ON
ON
OFF
ON
ON
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
CLOSING (max 7 pairs)
ON
OFF
OFF
ON
ON
OFF
ON
OFF
ON
OFF
ON
ON
ON
ON
OFF
OFF
ON
ON
OFF
ON
ON
ON
ON
OFF
OFF
ON
OFF
OFF
OPENING and CLOSING (max 2 pairs)
OFF
ON
OFF
ON
ON
ON
ON
ON
OPEN PULSE (1 pair)
Connection of BUS G-WAY photocells
For connecting you have to use two cables without polarity (see the specific device instructions).
DL1
= Alignment
DL2
= BUS G-WAY status/
Power
supply
DS1
= Programming
Dip-switches